Origin
When the amplitude of a vibration of frequency f is modulated, that is, it rises and falls periodically at another frequency m, the spectrum does not show a single peak. The central peak appears at f and, on either side, there are peaks at f plus m, f minus m, and sometimes at multiples of m. The spacing between the side peaks and the central peak is the modulating frequency, and that is what makes them useful: it tells you which phenomenon is doing the modulating.
What they indicate in each case
- Gears: around the gear mesh frequency, sidebands appear spaced at the rotating speed of the problem gear. They point, for example, to eccentricity or damaged teeth on that gear.
- Bearings: inner race defect frequencies are modulated by the rotating speed, since the defect enters and leaves the load zone. Sidebands spaced at the rotating speed point to a defect in the element that rotates with the shaft.
- Electric motors: sidebands at the pole pass frequency around the rotating speed may be related to problem rotor bars. The pole pass frequency is the slip multiplied by the number of poles.
- Looseness or rubbing: these can modulate other peaks.
How to analyze them
- Locate the central peak and measure the distance to its sidebands.
- Compare that spacing with rotating speeds and other known frequencies of the machine.
- Observe whether the number and height of the sidebands grow over successive inspections, which usually indicates a developing fault.
Measurement requirements
Separating the sidebands requires sufficient spectral resolution relative to the spacing: if the resolution is coarse, the peaks merge into a single wide one. The machine must also be running in a steady state, because a fluctuating speed widens and blends the peaks.
A caveat
Sidebands are not a fault in themselves, but a clue. Many healthy machines show some. What matters is the spacing, the growth and the context.