What it offers compared with measuring axis by axis
With a uniaxial sensor, one direction is measured at a time and the sensor has to be repositioned, which adds mounting differences between readings. A triaxial sensor delivers the three channels (generally horizontal, vertical and axial) simultaneously, with a known fixed geometry between axes. This saves time and makes it possible to compare phases between directions at the same instant.
How it is measured
- Choose a rigid, flat, clean point close to the vibration source.
- Identify the sensor axes (marked on its body) and align them with the machine directions; document the orientation.
- Attach the sensor with a method that preserves the required bandwidth.
- Connect it to an analyzer with three input channels, or to a collector that multiplexes them, and verify that each channel is assigned to the correct axis.
What it is used for
- Distinguishing unbalance (predominantly radial) from misalignment (significant axial component).
- Characterizing vibration in structures, bases and piping where the dominant direction is not known in advance.
- Assessing the vibration levels of an environment, where the result depends on the combination of the three directions.
How to interpret the result
Each channel is analyzed with its own spectrum and compared with the other two. If the axis with the highest amplitude is not the one expected, there is usually a resonance or a poorly documented orientation. The combined vector magnitude is used when an evaluation criterion calls for it, but it does not replace analysis by direction.
When it does not apply
A small triaxial sensor has frequency or range limits that may not cover the defect being sought. For detailed bearing diagnostics, a high-frequency uniaxial sensor in the load direction is usually preferred.