System components
A typical system consists of modules, a pump controller or variable frequency drive with maximum power point tracking, a submersible or surface pump, piping, sensors and a tank. In its most common form it is a battery-free system, because storing water in a tank is simpler and more durable than storing electrical energy.
How sun relates to flow rate
The available power varies throughout the day. The controller adjusts the pump speed to make use of it. For a centrifugal pump, the flow rate is roughly proportional to the speed, and the head it reaches grows with the square of the speed. For that reason, at low irradiance the pump may turn but fail to reach the required head and deliver no water.
What data define the design
- Daily water volume required and its seasonal variation.
- Total head: elevation difference from the water level to the discharge, plus friction losses in the piping.
- Well characteristics, such as the drawdown of the level during pumping.
- Pump curve and its operating point.
- Solar resource at the site in the worst month.
Usual protections
It is usual to include dry-run protection, with a level sensor or by low-load detection, overcurrent protection and tank level control to stop pumping when the tank is full. Dry running can damage a submersible pump, which depends on the water for cooling.
What to check first if it delivers less water
Verify the dynamic water level in the well, the array voltage and current, the presence of shading or soiling, and whether the pump is working in its efficient range. Sometimes the problem is hydraulic, such as leaks, partially closed valves or pump wear, and not electrical.
Notice
Any work on an energized photovoltaic array, with DC voltages that are not interrupted by opening a disconnect switch on the AC side, must be carried out by qualified personnel in accordance with the applicable electrical safety regulations. Tasks at the well and with submersible equipment are likewise the responsibility of trained personnel.