Leather glove over a dielectric glove: when is it necessary?

The leather glove is worn over the dielectric glove to protect it from cuts, abrasion and mechanical punctures, because insulating rubber is thin and vulnerable; leather on its own does not insulate.

Each glove has a different function

The dielectric glove provides electrical insulation. The leather glove, worn on top, provides mechanical protection. Combining them any other way, for example using only the leather in electrical work, leaves the person without insulation; using only the rubber in a task with sharp edges or friction puts the glove’s integrity at risk.

Why rubber needs protection

The insulating material must be flexible and relatively thin to allow dexterity. A small cut, a puncture from a burr or repeated rubbing can create a weak spot where current finds a path. And the damage is not always visible. The leather acts as armor against these events.

Situations where it is necessary

  • Work with tools, screws, terminals or surfaces with sharp edges.
  • Handling objects that can rub or puncture.
  • Equipment operations where there is friction with hardware or mechanisms.
  • Any task where the procedure or the manufacturer specifies its use, according to the glove class and the risk.

When going without it is justified

When the task demands great sensitivity and the risk analysis concludes that the mechanical risk is low, the procedure may allow the insulating glove to be used without a protector, provided that the applicable regulations and the manufacturer’s instructions allow for it. This is a documented decision, not a habit.

Details of use

  1. The protector is fitted so that it is not loose and does not leave the cuff area exposed.
  2. The leather must not contain metal parts that could come into contact with energized parts, and it must not be contaminated with grease.
  3. The protector is inspected together with the glove; if it is torn or hard, it is replaced.
  4. The leather glove never replaces the rubber glove under any circumstances.

What to check first

Confirm the task procedure and the glove instructions. Work involving electrical risk must be carried out by qualified personnel in accordance with the applicable regulations.