What each term means
In this context, in-house rescue is performed by a team from the facility itself, designated, trained and present during the entry. External rescue is provided by an outside service, such as the fire department, civil protection or a specialized company. It should not be confused with “non-entry” rescue, which is a technique and can be used by either team.
Comparison
| Criterion | In-house | External |
|---|---|---|
| Response time | Immediate, on site | Depends on distance and availability |
| Knowledge of the space | High, if the team knows the site and practices there | Limited, unless there have been prior visits |
| Rescue experience | Depends on training and practice | Usually greater |
| Equipment | Purchased and maintained by the company | Supplied by the service |
| Commitment | The company’s own responsibility | Requires an agreement and confirmation of availability |
The decisive criterion: time
When someone is left without breathable air, minutes matter. A service that takes longer than the person can survive is no use as a rescue plan, however good it may be. If the space presents an immediate danger to life, the team normally has to be on site, ready and equipped. In lower-risk spaces, an external service with compatible response times may be sufficient.
Conditions for either one to work
- The rescuers know the hazards of the space and its layout.
- They have suitable equipment: self-contained or supplied-air breathing apparatus, harness, lifeline, hoisting means and a stretcher.
- They have practiced the rescue in a similar space or in the same one.
- Before each entry, it is confirmed that they are available and that they understand the task.
Common combinations
The most common arrangement is a mixed one: the attendant activates non-entry rescue with the plant’s equipment, and the external service provides support with medical care and technical rescue. Calling an emergency number is not a plan in itself; the plan defines who does what in the first few minutes.
How to decide
- Assess the hazard and how long a person can withstand it.
- Estimate the real arrival time of the external service.
- Choose in-house, external or mixed, according to what is compatible.
- Verify with drills.
Planning must be done by trained personnel, in accordance with the applicable regulations.
This guide is for information only. Work involving electrical hazards, heights or hazardous atmospheres must be carried out by qualified, authorized personnel, following the applicable regulations.