What is really being measured
The bearing rotates inside its housing, and the forces it generates travel through the outer ring to the casing. The sensor does not see the defect directly, but its effect as filtered by that path. The shorter and stiffer the path, the more faithful the signal.
Choosing the measurement point
- As close as possible to the bearing load zone, on solid metal and not on thin covers, sheet metal or guards.
- On a flat, clean surface free of thick paint or loose rust.
- Always at the same points on each visit, so that comparisons are valid.
Directions
The radial directions (horizontal and vertical) and the axial direction are usually taken. The horizontal direction tends to be more flexible in machines on a base, so it often shows amplitudes different from the vertical, and the axial direction helps to distinguish misalignment or thrust problems.
Mounting matters
A stud or rigid adhesive preserves the high-frequency content. A magnet or a hand-held probe introduces a resonance of its own that limits the usable band. For detecting bearing defects, which live at high frequencies, poor mounting can hide exactly what you are looking for. A poorly seated sensor also generates false peaks.
Which variable to use
Velocity is used for the overall severity of the machine. For bearing defects, acceleration is used, often with demodulation or enveloping, because the defect impacts excite high-frequency resonances.
How to interpret the result
The spectrum is evaluated by looking for the characteristic bearing frequencies (races, rolling elements and cage) and their harmonics, and is compared against the baseline and the trend. A stable condition is normal; a sustained rise in the level or the appearance of sidebands indicates deterioration. The operating load and speed must be recorded with each measurement.