How is an automotive component environmentally qualified?

An automotive component is environmentally qualified by defining its mission profile and location in the vehicle, and subjecting it to temperature, humidity, vibration, dust, water and chemical tests consistent with that profile.

Starting point: where the component goes

Environmental severity depends on location. A module in the passenger compartment does not suffer the same conditions as one in the engine compartment, under the floor or mounted on a wheel. Location determines the temperature range, splash exposure, vibration and the fluids the component may touch.

The mission profile

This describes how the component lives: operating hours, start cycles, time at rest, climates, years of service and number of events. The tests and their duration are derived from this profile, often with the help of acceleration models based on the relevant failure mechanism.

Usual tests

  • Thermal: exposure to extreme temperatures, cycling and thermal shock, with the component operating or switched off.
  • Humidity: steady and cyclic exposure, with condensation.
  • Mechanical: vibration with profiles according to the mounting, and shock.
  • Water and dust ingress: according to the required degree of protection.
  • Corrosion: salt spray or cyclic tests.
  • Chemical: contact with fuels, oils, cleaning fluids and other fluids present.

How it is organized

Samples are distributed through a test sequence, so that each unit accumulates several exposures and the interaction between them is uncovered. Electrical tests specific to the vehicle, such as supply voltage variations, are also included, but those belong to another family.

Acceptance criteria

The component’s function is defined for each state: operating during the test, degraded but recoverable, or no failure permitted. Its performance is recorded before and after. Small drifts are information about wear.

Which source to follow

Each vehicle manufacturer and each supplier tier usually has its own specifications, in addition to industry standards. Qualification is based on those required by the customer or the contract. The current edition of each one must be consulted, because the test program can change between revisions.