What changes compared with a chamber
In an open field there are no walls to reflect, but there is ground, and there is no shielding against outside emissions. This defines the difficulties: ground reflection adds to the direct signal and radio signals from the surroundings enter the measurement. Weather and terrain also have an influence.
Site preparation
- Clear ground. No buildings, fences, trees or vehicles near the path between the antennas that could generate reflections. A nearby obstacle appears as ripple in the measured pattern.
- Prior spectrum survey. A spectrum analyzer and an antenna are used to check whether there are signals in the band of interest. If there are, change the frequency or the time of day, or use a selective receiver with a narrow bandwidth.
- Distance. At least the far-field distance of the larger antenna; insufficient distance broadens the lobes and fills in the nulls.
Ground reflection
The wave reflected from the ground arrives with a delay relative to the direct wave and can reinforce or weaken it, depending on the antenna heights and the distance. It can be handled in two ways. At a test site with a conductive ground plane, this reflection is a controlled part of the method, and the height that gives the maximum signal is sought. To measure the free-space pattern, the antenna is raised and the beam is oriented so that it points away from the ground, or absorbing material is placed where the reflection strikes.
Setup
- Use masts and supports made of non-metallic materials, or with very little metal structure near the antenna.
- Align the antennas and set the polarization.
- Run the cables perpendicular to the antenna or underneath it, to limit their radiation and coupling.
- Measure the transmission with a network analyzer or with a generator and receiver.
- Rotate the antenna under test and record the signal by angle.
- Repeat at different heights to see the effect of the ground, and compare against a reference antenna if gain is needed.
How to interpret and validate the result
Repeatability is the most practical test: if the pattern changes when the antennas are moved slightly or with the time of day, there is uncontrolled interference or reflections. A pattern with rapid, regular ripple suggests a nearby reflector.
It is advisable to record the environmental conditions and the configuration, because rain, soil moisture and wind alter the result. Transmitters may be subject to outdoor emissions regulations and must be used with the corresponding permits.