Which signals matter
A switching converter produces fast, high-amplitude signals in a small space, so almost all problems become visible by relating three things: the voltage at the switching node, the current flowing through the inductor and the output voltage.
The switching node
It shows the duty cycle, the rise and fall times and the ringing after each transition, caused by parasitic inductances and capacitances. Excessive overshoot stresses the semiconductors and is a source of interference.
The inductor current
It is measured with a current probe or a sense resistor. Its triangular shape reveals the conduction mode, inductor saturation, which appears as a sharp increase in slope, and current limiting.
The output
It is examined with AC coupling and a short ground connection to see the ripple and spikes. Applying a load step shows the response of the control loop: a long overshoot or sustained oscillation indicates a small stability margin.
General procedure
- Start with the input supply at a reduced value and no load, and increase gradually.
- Trigger on the switching node and measure frequency and duty cycle.
- Compare the inductor current with what the design predicts.
- Apply load steps and observe the recovery of the output.
- Repeat at the extreme input and load conditions.
Measurement precautions
- Use minimal ground connections, because fast edges are very sensitive to the probe loop.
- If the probe is referenced to a node that swings, such as the high side of a bridge, use a differential or isolated probe, never the oscilloscope ground.
- Verify that the probes can withstand the input voltage and the spikes.
How to interpret the result
If ringing on the switching node changes when you change the probe or connection, part of it may come from the measurement. If it stays the same, it points to the printed circuit layout or the choice of components. Measurements on energized circuits or at hazardous voltages must be made by qualified personnel, following the applicable safety regulations and using accessories with the appropriate category and rated voltage.