Solar energy

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • What does the IEC 61215 standard test in modules?

    The IEC 61215 standard defines a test sequence for qualifying the design of a terrestrial photovoltaic module: it verifies that the module's electrical performance and integrity are maintained after it is subjected to representative environmental and mechanical stresses.

  • What does the IEC 61730 standard evaluate regarding safety?

    The IEC 61730 standard evaluates the safety of a photovoltaic module: that its construction and materials withstand the risk of electric shock, fire and mechanical injury throughout its service life, and it defines tests to verify this.

  • What does the IEC 62109 standard cover for inverters?

    The IEC 62109 standard deals with the safety of power converters for photovoltaic systems, including inverters: it requires them to protect against electric shock, hazardous energy, fire and failures, and to detect and handle ground faults.

  • What is a microinverter?

    A microinverter is a small inverter connected to one or two modules that converts direct current into alternating current right on the roof and lets each module work independently.

  • What is a power optimizer?

    A power optimizer is a DC-DC converter fitted to each module so that it works at its maximum power point, while conversion to alternating current is still done by a string inverter.

  • What is a pyranometer?

    A pyranometer is a sensor that measures total solar irradiance on a flat surface, in watts per square meter, and is the reference for evaluating how much sun a system actually received.

  • What is an I-V curve tracer?

    An I-V curve tracer is an instrument that sweeps the load of a module or string from short circuit to open circuit and records current and voltage, together with irradiance and temperature, to show its actual performance.

  • What is irradiance and how is it expressed?

    Irradiance is the power of solar radiation striking a surface per unit area and is expressed in watts per square meter; its integral over time is irradiation, in energy per unit area.

  • What is mismatch between modules?

    Mismatch between modules occurs when interconnected modules have different I-V curves and the whole yields less than the sum of its parts, because the lowest current governs in series and the lowest voltage governs in parallel.

  • What is nominal operating cell temperature?

    Nominal operating cell temperature (NOCT) is the temperature reached by a cell in a module mounted on an open rack, at open circuit, under 800 W/m² of irradiance, an ambient temperature of 20 °C and a wind speed of 1 m/s.

  • What is potential-induced degradation?

    Potential-induced degradation (PID) is a loss of module power caused by the voltage difference between the cells and the grounded frame, which promotes leakage currents and the migration of ions toward the cells, especially in the presence of humidity and heat.

  • What is the annual degradation of a module?

    Annual degradation is the fraction of power a module loses each year of operation. It is usually expressed as a percentage per year and is used to project the long-term production of a system and to understand power warranties.

  • What is the fill factor?

    The fill factor compares a module's actual maximum power with the product of its open-circuit voltage and short-circuit current; it shows how square the I-V curve is and reflects cell quality.

  • What is the I-V curve of a module?

    The I-V curve of a photovoltaic module represents the current it delivers at each voltage value across its terminals, under given conditions of irradiance and temperature; from it come the short-circuit current, the open-circuit voltage and the maximum power point.

  • What is the maximum power point?

    The maximum power point is the point on the I-V curve where the product of voltage and current is highest; the inverter searches for it continuously with a tracking algorithm because it shifts with light and temperature.

  • What is the performance ratio of a solar plant?

    The performance ratio of a solar plant compares the energy actually delivered with what an ideal system would have produced under the same irradiation; it sums up the losses from temperature, soiling, wiring, the inverter and availability.

  • What is the temperature coefficient of a module?

    A module's temperature coefficient indicates how much an electrical quantity, normally power, voltage or current, changes for each degree of variation in cell temperature; for power it is negative in silicon.

  • Why do cells break with microcracks?

    Silicon cells are very thin, fragile wafers. Microcracks appear as a result of mechanical and thermal stresses during transport, installation and operation, and they can grow with cycling until they isolate areas of the cell that stop producing.

  • Why do hot spots form in a module?

    A hot spot appears when a cell or group of cells dissipates power instead of generating it, normally because it becomes reverse biased within a string: the current from the healthy cells forces it to heat up.

  • Why does a DC connector fail?

    A DC connector almost always fails because of high contact resistance: a defective crimp, a poorly mated joint, moisture or connectors that are not compatible. That resistance heats up, gets worse over time and can end in an arc.

  • Why does a solar array produce less than expected?

    A solar array produces less than expected when one of the actual losses exceeds what was forecast, or when the actual solar resource was lower than assumed. To find out which, compare the measured energy with a model fed with the recorded irradiance and temperature.

  • Why does an inverter disconnect on grid voltage?

    An inverter disconnects on grid voltage when the voltage at its terminals rises above or falls below the protection limits. With solar generation, the most common case is overvoltage caused by the voltage drop of the injected current itself on a weak grid.