24/7 emergencies 814 777 6921812 230 6079WhatsApp 811 786 0768
Electrónica MonterreyElectrónica MonterreyLaboratorios Creativeit Talk to an engineer
Menu

What is an I-V curve tracer?

An I-V curve tracer is an instrument that sweeps the load of a module or string from short circuit to open circuit and records current and voltage, together with irradiance and temperature, to show its actual performance.

How it measures

The instrument connects a variable load, which may be electronic or capacitive, to the module and steps through the operating points between the short-circuit current and the open-circuit voltage. Each point on the curve is a pair of current and voltage values. At the same time, plane-of-module irradiance and temperature are recorded, because the curve only has meaning relative to those conditions.

Why it tells you more than measuring power

The power delivered by an inverter indicates only one operating point. The complete curve shows why a module is yielding less. The shape of the curve separates causes that look the same when seen only as an energy loss.

How to read the curve

  • Low current across the whole initial section: soiling, shading or degradation of the glass or cell.
  • Steps or notches: one or more groups of cells with bypass diode protection active because of shading or damage.
  • Steep slope near short circuit: loss of shunt resistance, for example from potential-induced degradation.
  • Rounded knee and low operating voltage: high series resistance from solder joints, connections or connectors.
  • Lower open-circuit voltage: high temperature or damaged cells.

What the engineer sees in the field

Each string is normally compared with the others and with the expected result for the measured irradiance and temperature. If the result is to be referred to standard test conditions, standardized correction procedures are applied, and the uncertainty depends mainly on the quality of the irradiance measurement. Without a well-oriented reference sensor, the result is only qualitative.

When it does not work well

With unstable irradiance, passing clouds or wind that changes the module temperature, the sweep is not representative. Nor is it useful for diagnosing problems outside the generator, such as inverter or communication failures.

Notice

Connecting instruments to energized strings involves dangerous DC voltages. Any work on an energized PV array, with DC voltages that are not interrupted by opening a disconnect on the AC side, must be carried out by qualified personnel, following the applicable electrical safety regulations.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer