How it measures
The instrument connects a variable load, which may be electronic or capacitive, to the module and steps through the operating points between the short-circuit current and the open-circuit voltage. Each point on the curve is a pair of current and voltage values. At the same time, plane-of-module irradiance and temperature are recorded, because the curve only has meaning relative to those conditions.
Why it tells you more than measuring power
The power delivered by an inverter indicates only one operating point. The complete curve shows why a module is yielding less. The shape of the curve separates causes that look the same when seen only as an energy loss.
How to read the curve
- Low current across the whole initial section: soiling, shading or degradation of the glass or cell.
- Steps or notches: one or more groups of cells with bypass diode protection active because of shading or damage.
- Steep slope near short circuit: loss of shunt resistance, for example from potential-induced degradation.
- Rounded knee and low operating voltage: high series resistance from solder joints, connections or connectors.
- Lower open-circuit voltage: high temperature or damaged cells.
What the engineer sees in the field
Each string is normally compared with the others and with the expected result for the measured irradiance and temperature. If the result is to be referred to standard test conditions, standardized correction procedures are applied, and the uncertainty depends mainly on the quality of the irradiance measurement. Without a well-oriented reference sensor, the result is only qualitative.
When it does not work well
With unstable irradiance, passing clouds or wind that changes the module temperature, the sweep is not representative. Nor is it useful for diagnosing problems outside the generator, such as inverter or communication failures.