What it measures
The pyranometer measures the irradiance reaching a plane from the whole hemisphere, adding direct radiation, diffuse radiation from the sky and reflected radiation if the plane is tilted. Mounted horizontally it gives global horizontal irradiance; mounted in the plane of the modules it gives plane-of-array irradiance, which is the value relevant for comparison with production.
Main types
- Thermopile: a black surface absorbs the radiation and its heating generates a signal in millivolts. It responds to a broad spectrum and is the reference option in meteorology.
- Silicon photodiode: cheaper and faster, but sensitive to only part of the spectrum, so its accuracy depends on the light being similar to that used for calibration.
- Reference cell or module: not strictly a pyranometer; it responds like a PV module and is useful for comparison with modules.
What determines its quality
The response must be proportional to the cosine of the angle of incidence, the sensitivity must not depend much on temperature, and the spectral response must be uniform. Standardized classifications group instruments by these properties. Periodic calibration against a standard also matters, because sensitivity drifts over time.
What an engineer sees in the field
A sensor that is dirty, out of level, shaded by a nearby structure or has a fogged dome gives false values that translate into an incorrect performance index for the system. That is why its cleanliness, leveling and orientation relative to the plane of the modules are checked, and its reading is compared with that of a second sensor when possible.
How to interpret the reading
Under a clear sky, the daily curve should be smooth and symmetrical about solar noon. Sudden jumps indicate clouds or sensor faults. To estimate energy, irradiance is integrated over time, and to evaluate a system it is compared with the production measured over the same interval.