What is volume resistivity?

Volume resistivity is a material property that measures its opposition to the passage of current through its volume, independent of sample size; it is related to resistance through the geometry.

Definition

The resistance of a part depends on its shape. Volume resistivity removes that dependence: it is the resistance of a unit cube of the material, measured between two opposite faces. For a flat sample with electrodes, resistivity is obtained by multiplying the resistance by the electrode area and dividing by the thickness. It is expressed in ohm-meters or ohm-centimeters.

Difference from surface resistivity

Current can travel along two paths: through the volume and along the surface. Surface resistivity depends on the film of moisture and contamination covering the part, and is measured separately. In an insulator, the surface current is usually greater than the volume current and can mask it, so the measurement method uses a guard electrode to separate the two.

How it is measured

A DC voltage is applied to the sample between two electrodes and the current is measured. Because the current decreases over time due to dielectric absorption and polarization, a standard electrification time is defined before reading. An electrometer is used because the currents are so small. Sample conditions such as temperature and humidity are controlled and recorded.

What affects it

  • Temperature: the resistivity of insulators decreases rapidly as temperature rises.
  • Humidity: absorbed water lowers resistivity, especially in hygroscopic materials.
  • Field and application time: the measurement can depend on the voltage and on the instant of reading.
  • Contamination and ionic impurities.

How to interpret the result

It is used to compare insulating materials and to track degradation. A material with high resistivity is a good insulator against DC leakage, but that figure alone says nothing about its dielectric strength or its AC behavior, which are different properties. Remember also that the value varies with test conditions, so comparisons must be made under the same conditions.

When it does not apply

For conductive or semiconductive materials, other techniques are used, such as the four-point probe method. Measurements at high voltages must be carried out by qualified personnel in accordance with applicable regulations.