What is an isotropic radiator?

An isotropic radiator is an ideal, lossless point antenna that radiates the same intensity in all directions; it does not physically exist, but it serves as a reference for expressing directivity and gain.

A reference model

An isotropic radiator is a point source that emits power with equal intensity in all directions in space, with no internal losses. Its radiation pattern is a perfect sphere. It is a theoretical concept: it serves as a common point of comparison for real antennas, whose radiation is never uniform.

Why it does not exist

It can be shown that a real antenna radiating transverse electromagnetic waves cannot produce a uniform field distribution over the whole sphere with a defined polarization. This result is related to the impossibility of combing a sphere without leaving a point where the tangent field vanishes. As a result, even the simplest dipole has a pattern with directions of maximum radiation and nulls.

What it is used for

  • Gain reference: gain relative to an isotropic radiator is expressed in isotropic decibels (dBi). An antenna with 0 dBi in a given direction radiates there exactly as the ideal radiator would.
  • Calculating free-space propagation loss: the path loss expression is derived by assuming isotropic antennas at both ends and is then corrected with the actual gains.
  • Equivalent isotropic radiated power (EIRP): this is the power that would have to be fed to an isotropic radiator to produce the same power density as the real antenna in the direction of maximum gain. It combines transmitter power, line losses and gain.

A simple relationship with power density

At a given distance from an isotropic radiator, the power is spread over the surface of a sphere, so power density decreases with the square of the distance. For a real antenna, this is multiplied by its gain in the direction considered.

What to keep in mind

It should not be confused with a practical omnidirectional antenna. An omnidirectional antenna such as the dipole radiates uniformly in one plane only, and has nulls along its axis. The term isotropic is reserved for the three-dimensional ideal.