What is atmospheric transmittance in thermography?

Atmospheric transmittance is the fraction of infrared radiation that passes through the air between the object and the camera; it falls with distance and humidity, and the camera compensates for it with entered parameters.

Concept

There is air between the object and the camera, and air is not perfectly transparent to infrared. Atmospheric transmittance is the ratio of the radiation reaching the camera to the radiation that left the object, a number between zero and one. Besides absorbing, the air emits its own radiation according to its temperature, and this adds to the signal.

What reduces it

  • Distance: attenuation increases with the path length.
  • Humidity: water vapor is the main absorber in the band of common cameras, and a larger amount of vapor along the path reduces transmittance.
  • Carbon dioxide and other gases: they absorb in specific bands.
  • Particles and droplets: fog, rain, smoke and dust scatter the radiation and can make the measurement useless.

How it is compensated

The camera calculates the transmittance with a model that uses the distance, relative humidity and atmospheric temperature entered by the operator. With these data it reconstructs the original radiation. If the parameters are wrong or the air is far from normal, the correction loses quality.

When it matters and when it does not

At short distances, such as a panel a few meters away, attenuation is small and an error in the parameters barely alters the reading. At tens of meters, in an outdoor substation, with high humidity or with an overhead line, the effect is no longer negligible and the distance and humidity data must be the real ones.

What an engineer sees in practice

Two shots of the same object at different distances that give different temperatures, even with the same emissivity, are usually due to attenuation or spot size. That is why it is advisable to record distance, humidity and ambient temperature at each inspection.

If fog, rain or smoke is visible, the prudent course is to postpone the measurement rather than try to correct it.