What is C-rate?

C-rate expresses charge or discharge current as a multiple of the battery's rated capacity: 1C is the current that, in theory, fully discharges it in one hour.

Definition

C-rate is a way of normalizing current to the size of the battery. If the rated capacity is Q in ampere-hours, a current of 1C is I = Q in amperes. A current of 0.5C is half of that, and one of 2C is double. With a 10 Ah cell, 1C equals 10 A and 2C equals 20 A.

Relation to time

Ideally, the time for a full discharge is the inverse of the rate: at 1C it discharges in one hour, at 0.5C in two hours, at 2C in half an hour. This is only an approximation, because at high rates the usable capacity decreases and the real time is shorter than the theoretical one; C-rate is therefore a way of describing current, not an exact calculation of duration.

Why it is useful

Two batteries of different sizes can be compared at the same C-rate even though their absolute currents differ. A cell’s behavior, such as voltage drop, heating and wear, relates better to C-rate than to amperes, because it depends on the current relative to what the cell can deliver.

What changes with the rate

  • The voltage drop due to internal resistance grows with current.
  • The heat generated grows with the square of the current.
  • Measured capacity falls at high rates and at low temperature.
  • Fast charging at high rates increases the risk of lithium plating and accelerated aging.

How to read a specification

A manufacturer’s data give maximum continuous and pulse charge and discharge rates, always with an associated temperature and condition. An energy cell is designed for low rates and a power cell for high rates, at the cost of less energy per unit mass. A capacity result without its test C-rate is incomplete.