24/7 emergencies 814 777 6921812 230 6079WhatsApp 811 786 0768
Electrónica MonterreyElectrónica MonterreyLaboratorios Creativeit Talk to an engineer
Menu

What is beamwidth?

Beamwidth is the angular opening of an antenna's main lobe. It is usually taken between the points where the power falls to half the maximum, about three decibels down. The narrower the beam, the higher the gain tends to be.

Definition

Beamwidth describes how open or tight the main lobe of the radiation pattern is. The most widely used measure is the half-power beamwidth: the angle between the two directions, on either side of the maximum, in which the power density is half the maximum. This is equivalent to a drop of approximately three decibels. Another measure is the width between the first nulls, which is larger and describes the base of the lobe.

It is measured in each plane

An antenna can have a different beam in each plane. The width in the E plane and the width in the H plane can differ, which is why both are reported. A circular parabolic reflector produces a nearly symmetrical beam; a panel or sector antenna usually has a beam that is wide in one plane and narrow in the other, on purpose, to cover an area.

Relationship with gain

If the antenna concentrates energy in a narrower beam, the gain in that direction increases. For a single beam with no significant side lobes, directivity is approximately inversely proportional to the product of the two beamwidths. That is why high-gain antennas, such as microwave link dishes, have very narrow beams. This relationship is only approximate: it depends on the side lobes and the losses, which subtract from the total.

What determines beamwidth

  • The electrical size of the aperture: the larger the antenna in wavelengths, the narrower the beam.
  • The excitation distribution across the aperture: a uniform distribution gives the narrowest beam but high side lobes; one that tapers toward the edges lowers the side lobes in exchange for widening the beam.

What it means in practice

Beam Advantage Cost
Narrow More gain, less interference from other angles Demands precise pointing and is sensitive to movement of the support
Wide Broad coverage, tolerant of pointing errors Less gain, picks up more interference

To measure it, the maximum is identified in a cut of the pattern and the half-power points are located on either side. An asymmetrical pattern or a maximum offset from the mechanical axis indicates a problem with the antenna, the mounting or the measurement environment.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer