What does ASTM E1933 say about emissivity?

ASTM E1933 brings together test methods for measuring the emissivity of a surface with a radiometric camera and for compensating for it, so that the displayed temperature comes close to the true temperature.

The starting problem

The camera receives radiation that depends on the object’s temperature, but also on how well its surface emits, that is, on its emissivity, and on what it reflects from the surroundings. If the emissivity value set is not correct, the calculated temperature is wrong. On polished metals the error can be large, because they emit little and reflect a lot.

What kind of approach the standard proposes

The standard focuses on two related tasks: determining the emissivity of a surface with the camera itself and compensating for its effects when measuring. The general logic of methods of this type is to find the true temperature of an area by other means, for example a contact sensor or a tape of known emissivity, and to adjust the camera’s emissivity until its reading matches that reference. That adjusted value is then used on the rest of the surface of the same material and condition.

Why reflected temperature is also needed

The radiation the camera measures is the sum of what the object emits, what it reflects from the surroundings, and what the atmosphere contributes. The lower the emissivity, the greater the weight of the reflection. That is why procedures of this type include determining a reflected apparent temperature and capturing the measurement so that reflections from nearby sources do not distort the result.

What it looks like in an inspection

  • A clean copper bar gives very low readings with the default emissivity.
  • An area with paint or electrical tape, with high and known emissivity, gives readings closer to the true temperature.
  • An oxidized material changes its emissivity over time, so a value measured one day is not universal.

What to remember

Emissivity depends on the material, its finish, its temperature, the viewing angle, and the camera’s band. The standard provides a method framework, but the exact requirements are in its text; consult the current edition.