How is the effect of distance compensated for?

Distance has two effects: the object occupies fewer pixels and is averaged with the background, and the air attenuates the signal. It is compensated by moving closer, using a longer focal length and entering the real distance.

Two distinct effects

Distance influences the measurement through two independent mechanisms, and each one is corrected differently.

Geometric effect

Each pixel covers a larger area the farther away the object is. When the object does not fill several pixels, the reading mixes object and background and underestimates the hot spot. This cannot be corrected with software.

What to do:

  • Move closer until the object covers several pixels in each direction.
  • Use a lens with a longer focal length, which reduces the instantaneous field of view.
  • Choose a camera with more pixels if the usual work requires long distances.

Atmospheric effect

The air absorbs part of the radiation and adds its own. The camera compensates for this if it is given the real distance, the humidity and the air temperature.

What to do:

  • Measure or estimate the distance with a rangefinder, not by eye, at long distances.
  • Update the humidity and ambient temperature values.
  • Avoid measuring in fog, rain or smoke.

How to tell which one predominates

At a few meters, the geometric effect almost always dominates: the problem is the size of what is being measured. At long distances or in very humid air, the atmospheric effect gains importance. A good habit is to record the distance in the report, so that measurements can be repeated or compared.

An example

An insulator is measured at a certain distance and a reading is obtained; when the operator moves to half that distance, the reading rises. The increase indicates that the first value was affected by spot size. The closer value is adopted, and a note is made that the distant measurement underestimated the temperature.

When it does not apply

If the goal is only to detect whether there is an anomaly, not to quantify it, a greater distance may be enough. When approaching energized equipment, the safety distances and procedures indicated by regulations apply, and this is the responsibility of qualified personnel.