Which bands are involved
The atmosphere transmits infrared radiation in two main “windows”: mid-wave (approximately 3 to 5 µm) and long-wave (approximately 8 to 14 µm). Each type of camera is optimized for one of them.
How they behave
- Long-wave: this is the band in which objects at ambient temperature emit the most energy. It usually uses uncooled detectors (microbolometers), which are more compact and economical. Reflected solar radiation has little weight in this band.
- Mid-wave: usually employs cooled detectors and offers high thermal sensitivity. Being a band of shorter wavelengths, it favors the measurement of hot objects. It is more affected by reflected solar radiation and by surfaces that reflect bright sources.
What this means for inspection
An outdoor electrical or mechanical inspection in mid-wave can show sun reflections on polished metal that look like anomalies; in long-wave those reflections are less of a problem. On the other hand, for observing fast phenomena, high-temperature processes, or certain gases, mid-wave may be better suited.
How to choose
| Need | Usual preference |
|---|---|
| General electrical and mechanical inspection, outdoors | Long-wave |
| Buildings and envelopes | Long-wave |
| High-temperature or high-speed processes | Mid-wave |
| Imaging detection of certain gases | Depending on the gas, generally a specialized mid-wave camera |
What the band does not decide
The band does not correct a poorly set emissivity or insufficient resolution. In both, you need to know the material, the distance, and the surroundings. Nor is there a universally superior band: the choice depends on the application and on what needs to be measured.