Definition
A random vibration is not described by a repeatable waveform but by its statistical content. Acceleration spectral density indicates, for each frequency, how much acceleration power there is in a narrow band around it. Its units are acceleration squared divided by hertz, that is, g squared per hertz when acceleration is expressed in g.
How it relates to the overall value
Summing the spectral density over all frequencies, that is, taking the area under the curve, gives the mean square value of the acceleration. Its square root is the overall RMS value, often called grms. Two spectra with the same overall value can be very different: one with energy concentrated at low frequency and another at high frequency cause damage differently.
How to read the plot
It is shown on logarithmic frequency and density scales. A curve with straight segments indicates a specified profile: rising or falling ramps and a plateau. Peaks mark frequencies with more energy. When interpreting a test, the measured curve is compared with the reference curve and its tolerances.
Resolution and confidence
The density estimate is calculated from a signal measured over a period of time and divided into segments. The analysis bandwidth and the number of averages determine how closely the estimate resembles the true value. A very narrow bandwidth gives more detail and more statistical noise; a very wide one smooths out real peaks.
What it is used for
It specifies the vibration level of a random test, compares a measured environment with a test environment and is used in structural response calculations. With the product’s transfer function, the response at a point can be estimated. It also serves as a basis for estimating fatigue.
What to watch for
Confusing spectral density with the amplitude of a sinusoid is a common mistake. Nor can a single point on the curve be read as an acceleration that the product feels at that frequency; it is a density, which only takes on meaning when integrated over a band.