What is an airline respirator?

An airline respirator supplies breathable air from an outside source, a compressor with air treatment or cylinders, through a hose to the worker's mask, without the duration limit of a self-carried cylinder.

How it is made up

An airline respirator separates the air source from the person. A source is set up outside, which may be a compressor with filters and treatment systems or a bank of cylinders. From there, a hose carries the air to a mask or hood. At the point of use there is a regulator or flow control. The person breathes air from the line as long as there is supply, without depending on a cylinder carried on the body.

Air quality: the critical point

If the source is a compressor, the air must be truly breathable. That means:

  • Taking in air from a clean area, away from engine exhausts and vapors.
  • Filtering out oil, water and particles.
  • Monitoring carbon monoxide with an in-line monitor, which alarms if it appears.
  • Maintaining the compressor according to the manufacturer’s instructions.

An oil-lubricated compressor that overheats can generate carbon monoxide, so the monitor is a safety element, not an accessory.

Advantages

  • Virtually unlimited duration as long as the source is working.
  • Equipment on the person is lighter and less bulky than self-contained apparatus.
  • Less breathing effort and fatigue on long jobs.

Limitations

  • Hose: it limits distance and can tangle, snag or be cut. Its route must be protected.
  • Dependence on the source: a compressor failure or power outage interrupts the air.
  • Connections: they must be incompatible with other gas lines to avoid connecting a non-breathable gas by mistake.

When there is immediate danger to life

In atmospheres where an interruption of air would be potentially fatal, the line is combined with an escape bottle, a small portable supply that allows the person to get out if the line fails. This is the airline configuration with auxiliary emergency supply. Without that reserve, the line alone is not sufficient in those conditions.

Where it is used

On long jobs inside tanks or vessels, in cleaning, painting and abrasive blasting, where the worker stays in one place for a long time and the hose can be managed. Selection, inspection and use must be carried out by trained people, in accordance with applicable regulations.

This guide is for information only. Work involving electrical hazards, heights or hazardous atmospheres must be carried out by qualified, authorized personnel in accordance with applicable regulations.