What is a waveguide?

It is a hollow metal structure, normally rectangular or circular, that guides microwave electromagnetic waves with very low loss; it propagates signals only above a cutoff frequency that depends on its dimensions.

What it is and how it works

A waveguide confines and conducts electromagnetic waves inside a metal tube. The waves bounce off the walls and propagate in stable field configurations called modes. Because it is hollow, it has no center conductor, and the dielectric losses are practically those of air.

Cutoff frequency

The essential characteristic is that each mode has a cutoff frequency determined by the cross section. Below it the wave does not propagate; it is attenuated rapidly. That is why a waveguide behaves as a high-pass filter. For a given mode, the cutoff frequency is inversely proportional to the transverse dimension, so waveguides for lower frequencies are larger.

Modes

  • TE (transverse electric). The electric field has no component in the direction of propagation.
  • TM (transverse magnetic). The magnetic field has no component in that direction.
  • A hollow single-conductor waveguide cannot propagate a TEM mode, the one used by coaxial lines.

In a rectangular waveguide the dominant mode, the one with the lowest cutoff frequency, is normally used. The recommended operating range is chosen between that cutoff frequency and that of the next mode, so that only one mode propagates.

Properties

  • The phase velocity is greater than the speed of light, and the wavelength inside the guide is longer than in free space. This violates no principle, because energy travels at the group velocity, which is lower than the speed of light.
  • It is dispersive: the group velocity depends on frequency.

When it is preferable to a coaxial line

Lower loss and higher power capacity at high microwave and millimeter-wave frequencies, where a coaxial line would be very small and lossy. But it is bulky, has no DC response and is band-limited. It is used in radar, satellite links and high-frequency laboratories, with coaxial transitions when connecting to instruments.