What it is and how it works
A borescope carries a miniature camera, or fiber optics, at the tip of a thin tube with its own lighting. The image is shown on a screen or recorded. It lets you look inside places the eye cannot reach: the interior of a motor, a heat exchanger, a pipe, a closed enclosure or the gap behind a panel.
Types
- Rigid: gives better image quality and is useful in straight sections.
- Flexible: bends to follow curves, and many models have an articulating tip to direct the view.
- Camera on a semi-rigid cable: a simple version for open spaces.
What it contributes to diagnosis
Inspecting without disassembling saves time and avoids introducing new damage, while also keeping the equipment in the state in which it failed. With it you can observe:
- Corrosion, deposits or obstructions in ducts.
- Wear, cracks or improper contact in internal components.
- Foreign object remains.
- Signs of overheating, such as surface discoloration.
- The condition of welds and wiring in hidden areas.
What an engineer sees in practice
The image is partial, with a narrow field of view, and close lighting can saturate it. Measuring sizes on the screen requires references or calibrated measurement functions; without them, a crack can look larger or smaller than it is. It is advisable to capture photographs with location references to compare later inspections.
When it does not apply
It is a visual technique: it does not detect defects that do not reach the surface, such as internal cracks in the material, and it does not measure electrical properties. Nor does it replace specific nondestructive tests. And it must not be inserted into energized equipment, enclosures with hazardous atmospheres or places with moving parts. Before inserting it, verify that the equipment is stopped and de-energized.
If the inspection takes place in installations with electrical risk, it must be carried out by qualified personnel in accordance with applicable regulations.