A laser emitter and receiver are attached to the two shafts, the shafts are rotated, and the parallel offset and angle are measured at the coupling plane; from those values the vertical and horizontal corrections for the movable machine are calculated.

Principle

A laser system has two units, one on each shaft. One emits a beam and the other receives it with a detector. As the shafts are rotated together, the beam spot on the detector moves according to the relative position of the shafts. From those readings at several angular positions and from the distances between units, feet and coupling, the instrument calculates the offset and angle at the coupling and the correction at each foot of the machine to be moved.

Preparation

  1. Lock out the machine and make sure it cannot start.
  2. Clean the seating surfaces and remove rusted or deformed shims.
  3. Check and correct soft foot before aligning, since a foot that does not seat falsifies the entire calculation.
  4. Check for play in the coupling, the condition of the bearings and the axial float.
  5. Confirm that there is no pipe strain on the casing.
  6. Mount the units on rigid brackets, without any flexing.

Measurement and correction

  1. Enter the required distances.
  2. Rotate the shafts to the indicated positions and record the readings.
  3. Read the result in the vertical and horizontal planes.
  4. Correct the vertical plane first with shims, and then the horizontal plane by moving the machine.
  5. Tighten the anchors and measure again; repeat if necessary.

What to consider

  • Thermal growth: in machines that change temperature during operation, the shafts shift; alignment is done to a target value set by the manufacturer or by experience, not to zero when cold.
  • Tolerance: it depends on the speed and the type of coupling; it is taken from the manufacturer’s recommendations.
  • Bracket flexure: over long distances it can alter the reading.

How to verify

After the correction, the measurement is repeated and compared with the tolerance. A good practice is to measure again after a period of operation. All work is done with the machine stopped and locked out, and by trained personnel.