Why acceleration is measured
According to Newton’s second law, the acceleration of a mass is proportional to the force acting on it. In vibration testing, this relationship makes acceleration the natural quantity for specifying and verifying test severity. Accelerometers also cover a wide frequency range.
Two distinct sensor functions
- Control: an accelerometer, normally at the interface between the table and the fixture, provides feedback to the controller so that it reproduces the specified excitation profile.
- Response: other accelerometers are placed at points of interest on the specimen to see how it amplifies or attenuates the excitation.
Mounting
The sensor must be attached with a screw, adhesive or a suitable stud, on a flat surface. Flexible mounting introduces resonances of its own and disturbs the control. The fixture between the specimen and the table must also be rigid within the test band; if it has resonances of its own, the controller compensates for them poorly and the specimen receives an excitation different from the one specified.
Cable and electronics
The cabling must be secured so that it neither generates triboelectric noise nor drags mass along. The complete measurement chain is verified with a vibration calibrator before the test. The bias or signal conditioner must match the type of sensor.
What to check first
- That the control sensor is at the point and in the direction defined by the procedure.
- That there is no saturation or clipping in the channels.
- That the coherence between control and response is reasonable at the frequencies of interest.
A test bench moves considerable masses with significant energy; it must be operated by trained personnel, following the equipment’s safety procedures.