- What does ISO 1940-1 classify in balancing?
ISO 1940-1 classifies the balance quality of rigid rotors through balance quality grades that make it possible to determine the permissible residual unbalance according to the rotor type and its service speed.
- What does the ISO 20816 series set out for machine vibration?
The ISO 20816 series sets out how to measure and evaluate the mechanical vibration of machines, with parts for different machine types, and defines the quantities, the measurement positions and the criteria used to classify vibration condition.
- What guidance does ISO 13373-1 give on monitoring?
ISO 13373-1 offers general guidance for machine condition monitoring using vibration: how to plan the program, choose parameters and transducers, and acquire and manage data consistently.
- What is a MEMS accelerometer?
A MEMS accelerometer is an acceleration sensor made of silicon with a microscopic structure that deflects under acceleration, and it measures that deflection electrically, generally through a change in capacitance, with a response down to zero frequency.
- What is a moving-coil velocity sensor?
A moving-coil velocity sensor is an electromagnetic transducer in which a coil moves within a magnetic field and, by induction, generates a voltage proportional to the vibration velocity, with no need for an external power supply.
- What is a two-channel FFT analyzer?
A two-channel FFT analyzer measures two signals simultaneously and calculates, in addition to the spectrum of each one, the relationships between them: relative phase, transfer function and coherence, which makes it possible to study how a system responds to an excitation.
- What is a vibration data collector?
A vibration data collector is a portable instrument that records vibration measurements at defined points on many machines following a route, stores them and transfers them to analysis software for viewing trends and diagnosing faults.
- What is a vibration spectrum (FFT)?
It is the representation of a vibration signal as a function of frequency, obtained with the fast Fourier transform, which breaks the signal down into its sinusoidal components and shows the amplitude of each one.
- What is an eddy current proximity sensor?
An eddy current proximity sensor is a non-contact probe that measures the distance to a conductive metal surface by detecting how the currents induced in it alter the probe's own field.
- What is ball pass frequency?
Ball pass frequency is the frequency at which the rolling elements of a bearing pass a fixed point on a raceway, and it appears in the vibration spectrum when that raceway has a defect.
- What is critical speed?
The critical speed of a rotor is the rotational speed that coincides with one of its natural frequencies, at which vibration increases noticeably because the rotor excitation enters into resonance with the system.
- What is mechanical looseness?
It is excessive play between parts that should be firmly joined, such as a bearing in its housing, a machine on its base or a component on its shaft, and it shows up as vibration with many harmonics and unstable phase.
- What is mechanical vibration and what quantities describe it?
It is the oscillatory motion of a machine or structure about an equilibrium position; it is described by its amplitude, frequency and phase, and the amplitude can be expressed as displacement, velocity or acceleration.
- What is phase in vibration analysis?
Phase indicates where a vibration is in its cycle relative to a reference, expressed in degrees, and it is used to determine how different points on the machine move relative to each other and to distinguish faults that have the same spectrum.
- What is rotation order in a spectrum?
Rotation order is a frequency expressed as a multiple of the machine's rotational speed: the first order is once per revolution, the second is twice per revolution and so on, which makes it possible to compare spectra at different speeds.
- What is rotor unbalance?
It is an uneven distribution of mass around the axis of rotation, so that the center of mass does not coincide with the axis and the rotation generates a centrifugal force that produces vibration at the rotating frequency.
- What is shaft misalignment?
It is a lack of coincidence between the centerlines of two coupled shafts, whether through a parallel offset, an angle between them or both, and it generates additional forces in the coupling and the bearings.
- What is the RMS value in vibration?
The RMS (root mean square) value is the measure of vibration amplitude that represents its energy content: the signal is squared, averaged over time and the square root is taken.
- Why do machine bolts come loose?
Bolts come loose because vibration, cyclic stresses and surface settling reduce the clamping force until the joint no longer maintains it, and once it loses preload, movement and loosening accelerate.
- Why does a bearing fail from poor lubrication?
A bearing fails from poor lubrication because, without a film separating the surfaces, metal-to-metal contact generates friction, heat and wear that damage the raceways and rolling elements until fatigue and cracks develop.
- Why does a fan vibrate after maintenance?
A fan vibrates after maintenance because its balance, alignment, mounting or clearance may have been altered during the work: cleaning, replacing or reinstalling an impeller or a bearing changes the mass distribution or the geometry.
- Why is there vibration at twice line frequency in motors?
Vibration at twice line frequency in a motor comes from the magnetic forces between stator and rotor, which depend on the square of the field and therefore repeat twice per cycle of the power supply.