How is a vibration alarm level defined?

It is defined by combining severity criteria by machine type with the machine's own baseline, setting at least one alert level and one danger level, which are adjusted with experience to limit false alarms.

What an alarm must achieve

An alarm level must give enough warning to act, without generating so many false warnings that they are ignored. That calls for references that are not the same for all machines.

Sources of criteria

  • Severity standards by machine class: they classify machines by size, speed and type of support and give evaluation zones for the overall velocity value. They are a general starting point; consult the current edition for their values.
  • The machine’s own baseline: the machine is measured in good condition and the alert level is set as a multiple of, or an increment over, that value. It reflects the real machine, with its own mounting and noise.
  • Manufacturer data: recommendations for specific machines.
  • Experience with similar machines: the plant’s failure history.

Types of alarm

  • On the overall value: one alert level and one danger level.
  • By spectral bands: separate limits for frequency ranges or for specific components, such as 1X, harmonics or bearing frequencies; they detect faults that the overall value does not bring out.
  • By trend: an alarm on rate of change, useful when the value is still low but rising fast.

How to adjust them

  1. Start with conservative criteria based on the machine class and the baseline.
  2. Observe during a period of normal operation.
  3. Correct levels that trip with no mechanical cause or that failed to warn of a real fault.
  4. Recalculate the baseline after repairs or operating changes.

An example reading

A pump with an overall value within acceptable limits but with a sustained rise week after week deserves attention before another that fluctuates with no trend. Alarm levels serve as a guide; they do not replace the analyst’s judgment or the decision to stop a machine, which depends on its criticality and the risk.