How is a rotor balanced in the field?

The 1X vibration is measured with its phase, a known trial mass is added at a defined angle, the change is measured, and from it the correction mass and angle are calculated, then installed and verified.

The idea behind the method

The vibration response of a rotor to an added mass is, to a good approximation, linear. If you know how much the vibration changes (in amplitude and phase) when a known trial mass is added, you can calculate what mass to place, and where, to cancel the effect of the original unbalance. This relationship is called the influence coefficient.

Before balancing

Not every high 1X is unbalance. The following must be ruled out first:

  • Misalignment, looseness, a loose base or resonance.
  • Buildup of product or dirt that can be removed.
  • A bent shaft or a thermal problem.
  • Bearing problems.

A phase reference is also needed, normally an optical sensor with a mark on the shaft, together with an accelerometer or velocity sensor.

Single-plane procedure

  1. Measure the initial 1X vibration: amplitude and phase, at a stable speed.
  2. Stop the machine and lock it out according to the procedure. Attach a trial mass at a known angle and a known radius.
  3. Start the machine, bring it to the same speed and measure the amplitude and phase again.
  4. Obtain the influence vector from the difference between the two measurements and the trial mass.
  5. Calculate the correction mass and angle; remove the trial mass and install the correction.
  6. Measure again. If residual vibration remains, make a trim adjustment.

Long rotors or rotors with couple unbalance require two-plane balancing, which uses an analogous procedure with cross coefficients between planes.

Critical points

  • Keep the same speed, the same sensor and the same conditions in all runs.
  • Define an angle convention, with or against the rotation, and do not change it.
  • The trial mass must cause a clear but not dangerous change.
  • Fasten every mass firmly: a loose mass is a projectile.

How to interpret the result

If the change with the trial mass is small, the machine has low sensitivity or there is another cause. If there is no improvement after the correction, look for another source of vibration. Work on rotating machinery is done with the machine locked out and by trained personnel, with the guards in place.