What the goal is
A route is an ordered sequence of points that are measured periodically with a data collector. Its value lies in the trend: what matters is how a point changes over time, not an isolated measurement. For the trend to be valid, the measurement must be taken the same way every time.
Steps to build it
- Select the machines: prioritize by criticality, consequence of failure, cost and ease of replacement.
- Define the points: normally each bearing support, near the load zone, in radial directions (horizontal and vertical) and axial where appropriate.
- Mark the points physically: with a mark or a fixed mounting base, so that the position can be repeated.
- Choose parameters and ranges: overall value in the appropriate quantity, a spectrum with a maximum frequency that covers the expected phenomena and sufficient resolution, and waveform when needed.
- Record the machine data: speed, number of poles, gear teeth and bearing geometry, in order to identify frequencies.
- Establish the baseline: measurements with the machine in good condition, which serve for comparison.
- Set the frequency: shorter intervals for critical machines or those with fast-developing faults, longer for those with slow-developing ones.
- Organize the route: by efficient physical walk-through and by hierarchy in the software.
Repeatability conditions
- Measure with the machine under similar operating conditions, noting load and speed.
- Use the same type of sensor and mounting, because the mounting mainly affects high frequencies.
- Keep the orientation and direction of each point.
How to maintain it
A route is not final. It is reviewed after repairs, process changes and detected faults: the points, the frequency and the alarm levels are adjusted. Measurements next to rotating parts must be taken in compliance with the plant’s safety procedures.