Electrical safety and PPE

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • What does NOM-029-STPS require?

    NOM-029-STPS sets safety conditions for maintenance activities on electrical installations in workplaces, in order to prevent risks to workers; its exact scope must be checked in the current edition.

  • What does the IEEE 1584 guide calculate?

    The IEEE 1584 guide provides calculation models for estimating arcing current, incident energy and the arc flash boundary from system data, equipment configuration and the protection's clearing time.

  • What effects does electric current have on the human body?

    The effects of current on the body depend on its magnitude, how long it flows, its path and whether it is direct or alternating; voltage matters only because, together with the body's resistance, it determines that current.

  • What is a lockout/tagout padlock?

    A lockout/tagout padlock is a padlock designed to hold an energy-isolating device in a safe position, with a unique or controlled key and identification of the person who fits it.

  • What is a risk analysis for an electrical task?

    A risk analysis for an electrical task identifies, before work begins, what can go wrong, how serious it would be and which controls will be applied, in order to decide whether the task can be done, under what conditions and by whom.

  • What is a two-pole voltage absence tester?

    A two-pole voltage absence tester is an instrument with two probes that connect to the circuit, whose indication depends on the actual voltage between them, with a defined internal impedance that limits ghost readings.

  • What is an approach boundary?

    An approach boundary is a distance around energized parts that defines who may cross it and with what protection: the limited approach boundary, the restricted approach boundary and the arc flash boundary are distinguished.

  • What is an arc flash and why is it dangerous?

    An arc flash is a sustained discharge of current through the air between conductors or to ground, releasing intense heat, light, pressure and molten metal in fractions of a second, capable of causing serious injury.

  • What is an electrically safe work condition?

    An electrically safe work condition is the state in which equipment has been disconnected from all energy sources, locked out and tagged out, tested for absence of voltage and, where appropriate, grounded, so that the work is no longer performed on energized parts.

  • What is an insulated hot stick?

    An insulated hot stick is a long-handled tool made of dielectric material that makes it possible to operate, test or handle energized equipment while keeping a safe distance between the hands and live parts.

  • What is ATPV?

    ATPV is the thermal energy value, expressed in calories per square centimeter, at which a material or garment has a 50% probability that the skin underneath will suffer a second-degree burn when exposed to a test electric arc.

  • What is electrical safety culture in a plant?

    Electrical safety culture is the set of shared habits, decisions and criteria that lead people to work safely even when no one is supervising them; it is not a poster or a rulebook, it is what happens under time pressure.

  • What is incident energy?

    Incident energy is the amount of thermal energy per unit area received by a surface, at a given working distance, during an arc flash; it is used to choose protective equipment and evaluate the risk.

  • What is indirect electrocution by step voltage?

    Indirect electrocution by step voltage occurs when a person touches no conductor, but their two feet are at points on the ground with different potentials because a fault current is dispersing into the earth.

  • What is let-go current?

    Let-go current is the highest current at which a person gripping a conductor can still open their hand voluntarily; above it, involuntary muscle contraction keeps them holding on and prolongs the exposure.

  • What is NFPA 70E and what does it cover?

    NFPA 70E is a U.S. standard for electrical safety in the workplace: it focuses on protecting people from electric shock and arc flash through risk assessment, an electrically safe work condition and the selection of protection.

  • What is the arc flash PPE category?

    The arc flash PPE category is a grouped level that links a task on a piece of equipment to a minimum arc protection value for clothing and accessories, so that incident energy does not have to be calculated in each case.

  • Why do arc flash accidents happen in electrical panels?

    Arc flash accidents in panels happen when something breaks down the insulation between phases or to ground, through contamination, tools, loose connections, wear or switching operations, and they get worse if the protection is slow to clear the fault.

  • Why does a lockout padlock fail in practice?

    In practice a lockout padlock almost always fails because of the procedure, not the padlock: it is placed at the wrong point, verification is skipped, someone else removes it, or energy arrives from a source nobody identified.

  • Why does a residual current device not protect against all contact?

    A residual current device detects current that leaks to ground, not just any contact: it does not protect if the current returns through the neutral, if contact is between two live conductors, or against leakage below its threshold.

  • Why does an induced-voltage shock occur?

    An induced-voltage shock occurs because a de-energized conductor that is close to energized lines or equipment, or exposed to a varying field or a lightning strike, acquires voltage through electric or magnetic coupling.

  • Why does sunlight degrade a dielectric glove?

    Sunlight degrades a dielectric glove because ultraviolet radiation and ozone break and rearrange the polymer chains, hardening the rubber and creating microcracks that reduce its insulating and mechanical capacity.