- What does the IEC 62305 series set out on lightning protection?
The IEC 62305 series sets out a comprehensive approach to lightning protection: general principles, risk assessment, protection of structures against physical damage and protection of internal electrical and electronic systems.
- What does the IEEE 80 substation guide cover?
The IEEE 80 guide deals with safety in the grounding of AC substations: how to calculate tolerable voltages, grid resistance, ground potential rise, and step and touch voltages.
- What guidance does IEEE 142 give on industrial grounding?
IEEE 142, known as the Green Book, gives guidance on grounding industrial and commercial systems: system grounding, equipment grounding, static, lightning protection and considerations for electronic equipment.
- What is a conductive ground enhancement backfill used for?
A conductive ground enhancement backfill reduces the local resistance between the electrode and the ground by replacing the immediately surrounding soil with a low-resistivity material that also retains moisture.
- What is a counterpoise in a grounding system?
It is a buried horizontal conductor, normally radial or parallel to a line, that is added to the electrode to disperse current when deep electrodes cannot be driven or when the impedance to lightning discharges must be reduced.
- What is a ground inspection well or pit?
A ground inspection well or pit is a box or tube with a cover, placed over the connection point of an electrode, that makes it possible to see, measure and maintain the connection without excavating.
- What is a ground rod electrode and what types exist?
A ground rod electrode is a metal rod driven into the ground to dissipate current; the main types differ in material and construction: solid copper, copper-clad steel, galvanized steel, stainless steel and chemically filled rods.
- What is a grounding electrode?
It is the conductive element, buried or in direct contact with the earth, that disperses the current of the grounding system into the soil; it can be a rod, a plate, a conductor, a ring, a grid or the steel of a foundation.
- What is a grounding system and what does it do?
A grounding system is the set of buried conductors and electrodes that connects an installation to the soil; its function is to provide a safe path for fault currents and keep potentials under control.
- What is a resistivity test rod used for?
A resistivity test rod is an auxiliary rod, driven temporarily into the soil, that serves as a current injection or voltage measurement electrode in four-electrode resistivity tests.
- What is an isolated ground and when is it used?
An isolated ground is an equipment grounding conductor insulated from the metal structure of the panel or conduit but connected to ground at the origin of the installation; it is used to reduce electrical noise in sensitive equipment.
- What is equipotential bonding?
Equipotential bonding joins the conductive parts of an installation with low-impedance conductors so that no dangerous potential differences exist between them.
- What is ground potential rise?
Ground potential rise is the potential difference between the grounding system and a point of remote earth, and it results from the current entering the soil multiplied by the resistance of the system.
- What is high-frequency ground impedance?
High-frequency ground impedance is the opposition a grounding system presents to rapidly changing currents, such as those of lightning, and it differs from its resistance to low-frequency AC or to DC.
- What is soil resistivity?
Soil resistivity is the opposition a volume of soil offers to the flow of current; it is expressed in ohm-meters and determines how much resistance a buried electrode will have.
- What is spreading resistance?
It is the resistance the soil offers to the current flowing from the electrode toward remote earth; it is not the resistance of the electrode metal, but that of the volume of earth surrounding it.
- What is system grounding versus equipment grounding?
System grounding connects a point of the circuit, normally the neutral, to ground to set its reference; equipment grounding connects exposed metal parts to provide a return for fault current and protect people.
- What measurement methods does the IEEE 81 guide describe?
The IEEE 81 guide describes how to measure soil resistivity, the resistance or impedance of grounding systems and surface potentials, including fall-of-potential methods and four-electrode arrays.
- Why do buried electrodes corrode?
Buried electrodes corrode because moist soil acts as an electrolyte: the corrosion can be galvanic from dissimilar metals, or caused by stray currents, soil composition or differences in aeration.
- Why does a ground conductor heat up during a fault?
Because the fault current dissipates energy in the conductor's resistance; the heating depends on the square of the current and on the time the protection takes to open, set against the conductor's cross-section and material.
- Why does an installation with good grounding still have noise?
Because a low resistance at the grid frequency does not guarantee low impedance at high frequencies, nor does it prevent ground loops, common-mode currents or badly made shield connections.
- Why does ground resistance change with the seasons?
Ground resistance changes with the seasons because it depends on soil resistivity, which in turn varies with moisture, temperature and dissolved salts, especially in the surface layers the electrode passes through.
- Why does ground resistance vary with the seasons?
Ground resistance varies with the seasons because soil moisture and temperature change, and these govern its resistivity: it rises in dry spells or frost and falls in the rainy season.
- Why is ground grid continuity lost over time?
Because buried conductors and joints are exposed to corrosion, mechanical stress and thermal cycling, and the weakest connection is the one that eventually opens while the rest of the grid appears to be fine.