The problem
The voltage of a string is the sum of the voltages of its modules in series, and that voltage changes with temperature. The inverter has two limits of interest: a maximum input voltage that must not be exceeded under any circumstances, and an operating window in which maximum power point tracking works. The string must fit within that window under all expected conditions.
The two design extremes
- Cold: at low temperature, open-circuit voltage is at its highest. With the string unloaded, for example when connecting it or when the inverter is not operating, the voltage must stay below the permitted maximum. Exceeding it can damage the inverter, and this is not a margin that can be negotiated. Use the minimum temperature expected at the site and the module’s voltage temperature coefficient.
- Heat: at high cell temperature, the voltage at the maximum power point is at its lowest. It must stay above the lower limit of the tracking window, or the inverter leaves the optimal zone and may stop producing.
General procedure
- Obtain the module’s open-circuit voltage and maximum power point voltage, and their temperature coefficients.
- Estimate the extreme cell temperatures at the site: the minimum and the maximum in operation.
- Calculate the open-circuit voltage of one module at the minimum temperature and the maximum power point voltage at the maximum temperature.
- Obtain the largest number of modules in series whose total in the cold does not exceed the inverter’s maximum voltage.
- Verify that the smallest number in series keeps the voltage in hot conditions within the tracking window.
- Verify that the current of parallel strings is compatible with the inverter input.
What an engineer sees in practice
The dominant constraint is usually cold for the maximum and heat for the minimum. A classic mistake is sizing with datasheet conditions rather than site conditions. The maximum system voltage ratings of the module and wiring also limit the design.
How to interpret the result
If no number of modules meets both extremes, change the inverter or the module, or separate the strings onto different inputs. Values must be taken from the datasheets of the specific equipment. Design with high DC voltages must be carried out by qualified personnel in accordance with current regulations.