How is shading measured at a site?

Shading at a site is measured by determining which part of the horizon and nearby objects blocks the sun at each moment of the year, using horizon survey tools or photographic analysis, and is expressed as an irradiation loss.

What measuring shading means

The aim is to find out how much of the available radiation is blocked by obstacles such as buildings, trees, antennas, neighboring structures or the array’s own rows. This is expressed as a fraction of irradiation lost over the year, or as a horizon profile. Shadows are not measured with a direct instrument; they are reconstructed from geometry and the position of the sun.

The basis: the sun path

The position of the sun at each hour and day of the year is known. It is represented on a diagram marking the sun’s altitude and azimuth. Overlaying the obstacle profile seen from the point of interest shows which moments of the year are blocked. A winter shadow with the sun low is more serious than a summer one, and a shadow at midday weighs more than one in the early morning because more energy arrives at those hours.

Usual methods

  • Instrument horizon survey: with a compass and inclinometer, or a sky-view device, the elevation angle of obstacles is noted in different directions.
  • Full-sky photography: an image with a fisheye lens, or a device that includes the superimposed sun path.
  • Three-dimensional site model, built from drawings or surveys, which simulates shadows by hour and day.
  • Inter-row shading study: geometric calculation of the minimum distance between rows to avoid self-shading during the hours of highest production.

What an engineer sees in practice

The results are carried into the production simulation as a loss factor. The electrical effect matters as much as the shaded fraction: a small shadow on one cell in a string can reduce production far more than its area, because of mismatch and bypass diodes. That is why it is advisable to identify which modules are shaded and how they are grouped into strings.

How to interpret the result

Every method has uncertainty, especially with growing vegetation or future obstacles, so the result is an estimate. The site is reviewed and the figures are updated for new construction or tree growth. Visits to roofs or arrays must be made with the applicable safety measures.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.