How is preventive maintenance of a solar array carried out?

Preventive maintenance of a solar array combines visual inspections, cleaning according to soiling, checks of connections and structures, periodic electrical tests and tracking of monitoring data, under a program defined by the plant.

What preventive maintenance aims to do

A solar array has no moving parts in its modules, but it does have degradation, soiling, connections that loosen with thermal cycling, and growing vegetation. Preventive maintenance aims to detect these changes before they reduce production or create a hazard. Its frequency and scope depend on the climate, the surroundings and the manufacturers’ recommendations.

Work areas

  • Modules: inspection of glass, frames, seals, discoloration and hot spots, and cleaning when soiling justifies it.
  • Structure and anchors: corrosion, fasteners, deformation and stability of the ground or roof.
  • Wiring and connectors: damage from ultraviolet radiation, rodents or chafing; loose or overheated connections.
  • Junction boxes and protection devices: fuses, disconnect switches, surge protection, seals and moisture ingress.
  • Inverters and transformers: filters, ventilation, alarms, fault logs and cooling condition.
  • Grounding: continuity and integrity of connections.
  • Surroundings: vegetation, new shading, drainage and access.

Periodic tests

Thermography under sufficient irradiance is the fastest tool for detecting hot spots and poor connections. String I-V curves and insulation resistance measurements make it possible to track the degradation trend. Each measurement must be accompanied by irradiance and temperature so it can be compared with previous ones.

Data analysis

Monitoring is part of preventive maintenance. Reviewing the performance ratio, comparisons between inverters and strings, and recurring alarms makes it possible to direct the visit to where it is needed, instead of repeating a blind routine.

What an engineer sees in practice

A program with a schedule, checklists, records and comparison with the commissioning baseline. Findings are classified by urgency: a burned connector is dealt with before a patch of soiling.

Interventions require isolating, locking out and verifying the absence of voltage, bearing in mind that modules generate whenever there is light. They must be carried out by qualified personnel in accordance with current regulations.