How does a string inverter work?

A string inverter converts the direct current from one or more module strings into alternating current synchronized with the grid, while seeking the maximum power point of each input and monitoring the grid and the insulation.

What it does

A string inverter receives at its inputs the direct current from one or more strings of series-connected modules and delivers alternating current to the grid. It is the point where the energy from the solar array becomes a usable product. It is called a “string” inverter in contrast to the central inverter, which groups many strings, and the microinverter, which is paired with a module.

Main stages

  1. Input and tracking: each input has a maximum power point tracker that adjusts the operating voltage to extract the most power from the connected array.
  2. DC conversion: in many designs, a boost converter adjusts the voltage of the internal DC bus, which widens the operating window.
  3. Inversion: a bridge of electronic power switches, using pulse-width modulation, generates an AC waveform from the DC bus.
  4. Filtering: filters reduce switching ripple to obtain a nearly sinusoidal current and limit harmonics.
  5. Grid connection: relays and protection devices isolate the unit when necessary.

Synchronization and grid functions

The inverter follows grid voltage and frequency through a synchronization loop and controls its current to inject power in phase. If the grid goes outside permitted limits, or is lost, the inverter disconnects and avoids feeding an uncontrolled island. Depending on the applicable regulation, it may also provide functions such as reactive power control or power curtailment.

Monitoring and protection

  • Monitoring of the array’s insulation to ground.
  • Overvoltage, overcurrent and overtemperature protection.
  • DC arc fault detection, in models that include it.
  • Event logging and communication with the monitoring system.

What an engineer sees in practice

Efficiency that varies with load, power derating when the unit heats up, insulation alarms after rain, and shutdowns when the grid is out of range. The ratio of array power to inverter power, and voltage compatibility, define performance.

Installing and maintaining inverters involves dangerous DC and AC voltages and must be carried out by qualified personnel in accordance with current regulations.