Short answer
NOM-009-STPS establishes the safety and health conditions for working at height, but it does not describe each piece of equipment in the necessary engineering detail. That part is complemented by personal protective equipment standards, manufacturing and testing standards for fall arrest components, and each company’s internal procedures.
What the NOM covers and where it falls short
The standard requires analyzing the work, authorizing people, training them, supervising and having rescue measures in place. It defines the what and the who. It does not tell you, for example, how to calculate the clearance needed below the worker or how a fall energy absorber behaves, and that is where the complements come in.
The most widely used complements
- Equipment standards: harnesses, lifelines, fall energy absorbers, connectors and anchors are specified and tested to product standards, normally national or international fall arrest equipment standards. They ensure that each part withstands the loads and behaves as the design assumes.
- Fall protection system standards: such as those in the ANSI Z359 series, which deal with the complete system and not just the part: anchorage, connection, harness and rescue.
- Confined space or energy control standards: when height coincides with another risk, such as energy lockout.
- Manufacturer’s instructions: these define the limits of use, inspection and service life of each component.
Why they have to be combined
A fall arrest system is a chain: anchor, connector, lanyard and harness. Each link can be certified and the assembly can still fail if the parts are not compatible, if the anchor does not withstand the load of a fall or if there is not enough clearance. That is why the complements are read as a system, not as isolated parts.
What an engineer sees in practice
A work-at-height analysis that chooses between preventing the fall (guardrails, restraint) and arresting it (fall arrest system), identified anchor points, equipment inspected before use and a rescue plan for the suspended worker, who cannot wait. Prolonged suspension in a harness is a medical risk in itself.
How to use this summary
Only the general scope is described here. Consult the current edition of NOM-009-STPS and of the applicable equipment standards. Work at height must be done by trained, authorized personnel, under supervision and in accordance with current regulations.
This guide is for information only. Work involving electrical hazards, heights or hazardous atmospheres must be carried out by qualified, authorized personnel, following the applicable regulations.