- What does the ANSI Z117.1 standard cover?
ANSI Z117.1 is a voluntary US consensus standard that sets minimum safety requirements for entering, working in and leaving confined spaces, and it complements mandatory regulations.
- What is a functional test (bump test) of a detector?
A functional test (bump test) briefly exposes a gas detector to a known concentration to check that its sensors respond and its alarms activate, but it does not adjust the calibration.
- What is a hazardous atmosphere?
A hazardous atmosphere is air in a space that can cause death, incapacitation, impairment of the ability to self-rescue, injury or acute illness through a lack or excess of oxygen, flammable gases or vapors, combustible dusts or toxic substances.
- What is a permit-required confined space?
A permit-required confined space is one that, besides being confined, contains or may contain a serious hazard, such as a hazardous atmosphere, a risk of entrapment or engulfment, or converging walls, and can therefore be entered only with written authorization.
- What is a rescue tripod with winch?
A rescue tripod with winch is a three-legged structure placed over a vertical entry that supports a hoisting system, a winch with cable and brake, to lower or retrieve a person without having to go in after them.
- What is a self-contained breathing apparatus?
A self-contained breathing apparatus (SCBA) is a respirator that carries its own air source, a compressed air cylinder connected to a mask through a regulator, so that the wearer breathes air independent of the surrounding atmosphere.
- What is an airline respirator?
An airline respirator supplies breathable air from an outside source, a compressor with air treatment or cylinders, through a hose to the worker's mask, without the duration limit of a self-carried cylinder.
- What is an authorized entrant?
An authorized entrant is the person designated to enter a permit-required confined space: they know its hazards, use the protective equipment, stay in communication and leave immediately at any sign of alarm.
- What is an entry attendant?
An entry attendant is the person who stays outside the confined space, watches over those working inside, keeps in communication with them and activates rescue in an emergency, without ever entering the space.
- What is considered a confined space?
A confined space is a place large enough for a person to enter and work in, with limited means of entry and exit, and not designed for continuous occupancy; its conditions, not its size, are what make it dangerous.
- What is hydrogen sulfide toxicity?
Hydrogen sulfide is a toxic, colorless gas with a rotten-egg odor that inhibits cellular respiration; at high concentrations it knocks out the sense of smell and can leave a person unconscious within a few breaths.
- What is inert gas asphyxiation?
Inert gas asphyxiation occurs when a non-toxic gas such as nitrogen, argon or helium displaces the oxygen in the air and a person is left without enough oxygen, with no odor, irritation or feeling of suffocation to warn them.
- What is oxygen deficiency?
Oxygen deficiency is an oxygen concentration in the air below what is needed to breathe safely; it can be detected only with an instrument, because it has no odor or color and the affected person's judgment deteriorates before they notice it.
- What is the entry supervisor?
The entry supervisor is the person responsible for verifying that the conditions for entering a confined space are safe, authorizing the permit, directing operations and canceling the entry when conditions change.
- What is the lower explosive limit?
The lower explosive limit (LEL, or LIE in Spanish) is the minimum concentration of a flammable gas or vapor in air at which the mixture can ignite; below it, the mixture is too lean to burn.
- What specific risks exist in a confined space?
The specific risks of a confined space arise from the combination of an atmosphere that can become hazardous, uncontrolled energies, engulfment, physical and thermal conditions, and the difficulty of communicating with and rescuing someone inside.
- Why do multiple deaths occur in confined spaces?
Multiple deaths occur in confined spaces because someone who sees a coworker collapse goes in to rescue them without protection and is exposed to the same atmosphere or hazard that incapacitated them, often within seconds.
- Why does a gas detector read zero in a hazardous atmosphere?
A gas detector can read zero in a hazardous atmosphere because it does not detect all gases, because its sensor is damaged, depleted or uncalibrated, or because the sample did not reach the sensor.
- Why does a gas sensor get poisoned?
A gas sensor is poisoned when certain substances in the air react with its sensing element or coat it and reduce its response; this is chemical damage, it is usually irreversible, and it can happen with no warning on the display.
- Why does communication with personnel inside the space fail?
Communication with personnel inside a confined space fails because the enclosure blocks or reflects the signal, noise and protective equipment make speech difficult, and a backup means is not always defined.
- Why does gas accumulate in low areas?
Gas accumulates in low areas when it is denser than air, because gravity settles it and poor ventilation prevents it from mixing; it also stratifies because of temperature and the shape of the space.
- Why is hot work dangerous in a tank?
Hot work is dangerous in a tank because heat, sparks or flame can ignite residual vapors in an enclosed space, and because welding consumes oxygen or generates toxic fumes in an unventilated enclosure.