- What is a borescope used for in diagnostics?
A borescope is a tube with a camera and a light, rigid or flexible, that allows the inside of inaccessible cavities to be visually inspected without disassembling the equipment.
- What is a capacitance meter with ESR?
A capacitance meter with ESR measures the value of a capacitor and its equivalent series resistance, which makes it possible to detect degraded capacitors that a capacitance meter alone does not reveal.
- What is a common cause failure?
A common cause failure is a single root cause that makes several items fail at the same time, including those installed as redundant, which is why it reduces the protection that redundancy provides.
- What is a component curve tracer?
A component curve tracer applies a voltage sweep to a device and displays its current-versus-voltage curve on screen, revealing its behavior without having to power the circuit.
- What is a component’s failure rate?
A component's failure rate is how often it fails per unit of time among those still working; how it evolves over time explains why equipment fails.
- What is a fault event recorder?
A fault event recorder is a device that continuously monitors electrical signals and saves, with a timestamp, the data from the moments before, during and after a disturbance.
- What is a fault tree?
A fault tree is a logic diagram that starts from an undesired event and breaks down, using AND and OR gates, the combinations of failures that can produce it.
- What is a latent failure?
A latent failure is a defect that already exists but has not yet shown itself, or a protective function that has stopped working without anyone noticing until it is needed.
- What is a logic analyzer for debugging?
A logic analyzer captures the digital state of many signals at once over time and shows the sequence, timing and protocols of a system so that logic errors can be debugged.
- What is an intermittent fault?
An intermittent fault is one that appears and disappears with no obvious pattern; it is due to a condition that is only met occasionally, such as a defective contact, a thermal effect or vibration.
- What is an ultrasound camera for leaks and discharges?
An ultrasound camera detects and locates the high-frequency sound produced by gas or air leaks and by electrical partial discharges, and displays it overlaid on a visual image.
- What is condition-based maintenance?
Condition-based maintenance intervenes on equipment when a measurement shows that its condition is deteriorating, not on a fixed calendar or after a breakdown.
- What is mean time between failures?
Mean time between failures, known by the abbreviation MTBF, is the average operating time between one failure and the next in a population of repairable equipment. It describes the statistical reliability of a population, not how long an individual unit will last.
- What is mean time to repair?
Mean time to repair, known as MTTR, is the average time that elapses from the detection of a failure until the equipment is working again. It summarizes how quickly a system recovers and includes diagnosis, logistics, intervention and return to service.
- What is root cause analysis?
Root cause analysis is a method for finding the original condition that made a failure possible, so that the correction eliminates the problem and not just its symptom.
- What is the P-F curve?
The P-F curve represents how a function deteriorates from the moment a defect becomes detectable (point P) until the equipment fails (point F); the time between the two points is the margin for action.
- Why does a connector degrade?
A connector degrades because its contact interface loses pressure or becomes contaminated: wear, corrosion, micromotion and temperature raise the contact resistance until they cause intermittent faults or heating.
- Why does a power resistor burn out?
A power resistor burns out when the power it dissipates exceeds what it can release to the environment, whether because of electrical overload, poor heat dissipation or an unforeseen operating condition.
- Why does a power transistor fail?
A power transistor fails from excessive junction temperature, overvoltage, overcurrent, avalanche or faulty switching, and the cause almost always lies in the surrounding circuit rather than in the device itself.
- Why does a solder joint detach from a circuit board?
A solder joint detaches when repeated mechanical or thermal stress exceeds what the joint can withstand, or when the joint was weak from the start because of poor metallurgical formation. The cause is almost always fatigue or a process defect, and rarely a sudden failure.
- Why does an electrolytic capacitor fail?
An electrolytic capacitor fails mainly through aging of the electrolyte, accelerated by temperature, ripple current and overvoltage, which raises its ESR and reduces its capacitance.
- Why does an electromechanical relay fail?
An electromechanical relay fails because its contacts degrade through electric arcing, because its coil is damaged or loses operating voltage, or because the mechanism wears out. The load and the number of operations determine which appears first.