How is a suspect capacitor checked?

A suspect capacitor is checked by visual inspection and by measuring capacitance and equivalent series resistance, ideally out of circuit and discharged, because an ordinary multimeter does not detect all defects.

First, discharge it

A capacitor can retain a dangerous charge after the equipment is switched off. Before touching or measuring it, it must be discharged in a controlled way and verified with an instrument to have no voltage. This is the first step and it is never skipped.

Visual inspection

On electrolytic capacitors, signs of failure are a bulging top, electrolyte residue, corrosion near the terminals or a deformed case. The absence of signs does not guarantee that it is good.

What is measured

  • Capacitance: a value far below nominal indicates electrolyte loss or aging. Electrolytic tolerances are wide, so the comparison is made against the manufacturer’s specification.
  • ESR (equivalent series resistance): this is the internal resistance that appears in series with the capacitance. It grows with aging and is the cause of heating and excessive ripple, even when the capacitance appears normal.
  • Leakage current: on electrolytics, high leakage indicates degradation of the dielectric.
  • Insulation or short circuit: on film or ceramic capacitors, a short is ruled out.

Why measure out of circuit

Other components in parallel alter the reading and can give misleading values. If it cannot be desoldered, at least one terminal is lifted. An in-circuit measurement serves as an indication, not a verdict.

How to interpret the result

A capacitor that passes on capacitance but has high ESR is degraded and fails in service, especially in switching power supplies. A correct value in a static test does not guarantee good performance under real ripple current and temperature. That is why replacement with a part of equivalent specifications is the usual course when there is reasonable doubt.

This work involves risk from stored energy; it must be carried out by qualified personnel in accordance with applicable regulations.