How do you diagnose a power supply that will not turn on?

To diagnose a power supply that will not turn on, check the input, the protection, the rectification, the control stage and the outputs in that order, separating a supply that is actually damaged from one that is protecting itself against a shorted load.

The logic of the diagnosis

A switch-mode power supply converts the mains into direct current, chops it with a power switch and rectifies it on the secondary side. If it does not start, the fault lies in one of these stages or in the load that forces it to shut down. The method is to follow the energy from input to output and stop where it no longer appears.

Safety first

The primary side operates at mains voltage and its capacitors can retain a dangerous charge after disconnection. Measurements on energized equipment must be made by qualified persons, with suitable instruments and insulation, and in accordance with the applicable regulations.

Check sequence

  1. Input: confirm that voltage reaches the connector and that the cable and the switch are in good condition.
  2. Input protection: inspect the fuse, the limiting thermistor and the varistor. An open fuse almost always indicates another fault; replacing it without looking for the cause usually repeats the damage.
  3. Rectification and primary capacitor: verify that the bridge rectifier is not shorted and that there is DC voltage on the main capacitor.
  4. Power switch and controller: a shorted transistor often accompanies an open fuse. The controller needs its own startup supply; without it, the power supply does not even attempt to switch.
  5. Secondary: check the rectifier diodes and output capacitors. A shorted diode causes the supply to go into protection.
  6. Feedback: if the optocoupler or the reference fails, the supply may shut down on startup or deliver the wrong voltage.

Telling a damaged supply from a damaged load

Many supplies enter protection mode and retry, which appears as periodic ticking or a brief flash at the output. Disconnecting the load and observing whether the supply starts separates the cases: if it starts with no load, the problem is downstream; if not, the defect is internal. A resistive dummy load confirms that it delivers the voltage under current.

What to check first

Before replacing components, look for bulging or leaking capacitors, burned components and cracked solder joints near the hottest components. Aged electrolytic capacitors are a frequent cause of failed startup or high ripple. An oscilloscope on the output shows whether there are startup attempts, and is more informative than a multimeter.