Environmental testing

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • What does dwell time mean in a thermal cycle?

    Dwell time is the period for which the temperature is held at one extreme of the cycle, once the sample has reached it, so that the sample stabilizes and the effects of the test develop.

  • What does ISO 9227 cover on salt spray?

    ISO 9227 specifies the equipment, reagents and conditions for corrosion tests in an artificial salt spray atmosphere, used to evaluate metals and coatings.

  • What does MTBF mean?

    MTBF stands for mean time between failures and is the average operating time between consecutive failures of a repairable product; it is neither the useful life nor the time after which the product fails.

  • What does part 2-14 of the IEC 60068 series cover on change of temperature?

    Part 2-14 of the IEC 60068 series describes change-of-temperature tests, with variants that differ in the rate of change and the medium used, to evaluate the effect of thermal transitions on a product.

  • What does the IEC 60529 IP code classify?

    The IEC 60529 IP code classifies the degree of protection an enclosure provides against access to hazardous parts, the ingress of solid objects and the ingress of water, but not against other hazards.

  • What is a climatic chamber?

    A climatic chamber is an insulated enclosure that controls temperature, and on many models humidity, to expose products to defined, repeatable environmental conditions.

  • What is a forced convection oven for testing?

    A forced convection oven is a heated enclosure with a fan that recirculates the air to achieve a uniform temperature, and it is used for thermal aging tests and for drying and curing samples.

  • What is a shock table?

    A shock table is a machine that applies mechanical shocks of controlled pulse shape and magnitude to a product to assess whether it withstands impacts, drops or handling.

  • What is a simulated solar radiation chamber?

    A simulated solar radiation chamber exposes a product to light from a lamp with a spectral distribution similar to that of the sun, together with controlled temperature, to study heating and radiation-induced degradation.

  • What is acceleration spectral density?

    Acceleration spectral density, or PSD, describes how the energy of a random vibration is distributed across frequencies, expressed as acceleration squared per unit of frequency.

  • What is an electrodynamic shaker?

    An electrodynamic shaker is an actuator that converts an electric current into mechanical force by means of a moving coil in a magnetic field, in order to vibrate products with controlled signals.

  • What is burn-in?

    Burn-in is a period of product operation, normally under elevated stress, intended to provoke and eliminate early failures before shipping to the customer.

  • What is HALT testing?

    HALT (Highly Accelerated Life Test) is a discovery test that subjects a product to increasing stresses until it fails, in order to find its weak points and design margins, not to demonstrate a service life.

  • What is the bathtub curve?

    The bathtub curve describes how the failure rate of a product population varies over time: high at the start, low and nearly constant during useful life, and rising at the end due to wear-out.

  • What is the MIL-STD-810 military method and what does it evaluate?

    MIL-STD-810 is a U.S. military environmental engineering standard that defines laboratory methods for evaluating how well equipment withstands the environments it will face during its life cycle.

  • What relative humidity is and how it affects electronics

    Relative humidity is the ratio between the water vapor present in the air and the maximum the air could hold at that temperature. In electronics it promotes corrosion, leakage and condensation, and its absence promotes electrostatic discharge.

  • What salt spray testing is and what it evaluates

    Salt spray is an accelerated corrosion test that exposes a sample to an aerosol of saline solution in a controlled chamber, in order to compare the resistance of coatings and materials to a corrosive environment.

  • What the Arrhenius acceleration factor is

    The Arrhenius acceleration factor expresses how many times faster a chemical or degradation process occurs at an elevated temperature than at the use temperature, according to an activation energy characteristic of the mechanism.

  • Why do solder joints crack after temperature cycling?

    Solder joints crack because the joined materials expand differently when the temperature changes, which imposes cyclic strains on the joint that accumulate fatigue until a fracture occurs.

  • Why does a product fail a humidity test?

    A product fails a humidity test because water, whether absorbed or condensed, reduces insulation resistance, opens leakage paths and accelerates corrosion and electrochemical migration.

  • Why does a product fail from vibration at resonance?

    At resonance, a structure amplifies the input vibration because the excitation frequency matches a natural frequency and damping is low, which raises stresses and accelerates fatigue.

  • Why does an enclosure with an IP seal fail the water test?

    An enclosure with a seal fails the water test because the seal is not properly compressed, is damaged or has aged, or because water gets in by another route, such as cable entries, screws or internal pressure changes.

  • Why does corrosion appear on connectors after salt spray?

    Corrosion appears on connectors because the conductive salt film and moisture attack the contact and plating metals, especially where there are galvanic couples, pores or worn plating.