What does part 2-14 of the IEC 60068 series cover on change of temperature?

Part 2-14 of the IEC 60068 series describes change-of-temperature tests, with variants that differ in the rate of change and the medium used, to evaluate the effect of thermal transitions on a product.

General scope

The IEC 60068 series brings together environmental test methods for electrotechnical products. Its part 2-14 deals with change-of-temperature tests: subjecting a sample to a transition between two extreme temperatures and observing whether it suffers damage or loses function. It differs from dry heat or cold tests, which hold a constant temperature.

Which variants it distinguishes

The document organizes the test into procedures that differ mainly in the speed of the transition and how it is achieved:

  • A rapid change, in which the sample passes from one environment to another in a short time, normally between two compartments.
  • A change at a specified rate, in a single compartment, where the ramp is what is controlled.
  • Variants with a liquid medium, for very abrupt transitions.

To find out which designation corresponds to each procedure and what its conditions are, the current edition of the standard must be consulted, as the details have been revised over time.

Which parameters are defined

For any variant, the method requires specifying the lower and upper temperatures, the dwell time at each extreme, the rate or time of transition, the number of cycles and the condition of the sample during the test, that is, whether it is operating or switched off. It also addresses temperature measurement, how to mount the sample, and the initial and final checks.

Why it exists

Temperature change generates stresses from differential expansion between materials with different coefficients of expansion, and thermal gradients within the part. These stresses fatigue solder joints, crack coatings, debond joints and deform seals. The test makes it possible to detect these effects in an accelerated way.

What the engineer sees

The standard is a test method and does not itself establish the pass criterion. Usually the product specification, or a product standard citing it, indicates the severity and what is considered a failure. Whoever runs the test must document the actual ramp of the sample, not just that of the chamber.

How to use it

It is recommended to consult the current edition before planning the test and to confirm with the product specification which variant and severity are required. Citing an out-of-date version is a common source of disagreement between the parties. The standard describes the method; the decision on what severity to apply rests with the product engineer and the applicable specification.