What is a shock table?

A shock table is a machine that applies mechanical shocks of controlled pulse shape and magnitude to a product to assess whether it withstands impacts, drops or handling.

What it reproduces

A shock is an abrupt change in velocity in a very short time. It represents impacts in transport, drops, railcar coupling, nearby explosions or the operation of mechanisms. The shock table makes it possible to reproduce these events repeatably, with a defined pulse rather than an arbitrary blow.

How it generates the pulse

In a common architecture, a table rises to a given height and falls along guides until it strikes a damper or pulse programmer. The pulse shape depends on the material and geometry of the programmer. Other configurations use compressed air or an actuator to accelerate the table. Shocks can also be produced with an electrodynamic shaker, with the controller governing the pulse shape, within the displacement and force limits of that equipment.

How a pulse is defined

A shock pulse is characterized by its shape, its acceleration amplitude and its duration. Typical shapes are half-sine, sawtooth and trapezoidal. The same acceleration peak with a different duration produces very different effects on the structure, because the response depends on how fast the pulse is relative to the natural frequencies of the product.

What is measured

An accelerometer on the table or the fixture verifies that the pulse meets the shape tolerances. Other sensors on the product show how it responds. Signal filtering is also controlled, as unsuitable filters distort the measured pulse.

Difference from vibration

Vibration and shock demand different things from the product. Vibration causes fatigue through repeated lower-energy cycles; shock demands withstanding an intense, brief event. A product can pass one and fail the other, for example because of a brittle solder joint or a poorly secured heavy component.

How to interpret the result

After the impacts, function is checked and the product is inspected for cracks, loosening and internal damage. The sample orientation and the number of events per axis must be defined in advance. Equipment of this type stores a great deal of energy and is operated only with the safety interlocks enabled.