Why is hot work dangerous in a tank?

Hot work is dangerous in a tank because heat, sparks or flame can ignite residual vapors in an enclosed space, and because welding consumes oxygen or generates toxic fumes in an unventilated enclosure.

Two hazards in one

Hot work, such as welding, cutting, grinding or using a flame, introduces an ignition source. A closed tank may contain what is missing for a fire or explosion: fuel in the form of vapors, gases or residues, and oxygen. In addition, the work itself alters the atmosphere. The combination of both hazards in an enclosure with limited exit is what makes it especially serious.

How ignition occurs

A fire needs fuel, oxygen and an ignition source. The flammable range of a vapor has a lower limit and an upper limit: below it there is not enough fuel, and above it there is not enough air. A tank that looks “clean” can release vapors from sludge, scale, coatings or porous walls when heated, and bring the atmosphere to a flammable point even after an acceptable reading has been measured.

Effects on the atmosphere

  • Oxygen consumption and displacement: combustion and welding shielding gases can displace oxygen.
  • Toxic fumes and gases: welding and cutting generate metal fumes and gases. Coatings and base metals can make them more toxic.
  • Oxygen enrichment: an oxygen leak from cutting equipment makes clothing and materials highly flammable.
  • Heat and loss of visibility for the worker.

What an engineer sees in practice

A specific hot work permit in addition to the entry permit, with combustible gas tests before and during the work, a fire watch, control of nearby combustible materials, ventilation and isolation of lines through which product could arrive. Attention is also paid to hidden points: whatever is on the other side of the wall being heated can ignite by conduction.

When not to start

If the atmosphere has not been reliably measured, if there is product that could re-enter, or if ventilation is insufficient, the work must not begin. If combustible readings rise during the work, it stops. This work must be planned and authorized by qualified personnel, following the applicable safety regulations.