General scope
The standard covers the balancing of rigid rotors, that is, those whose shape does not change appreciably under centrifugal force within their operating range. It defines how to specify the balance quality to be achieved and how to translate it into a permissible residual unbalance.
The idea of a quality grade
Instead of giving a single limit, the standard groups rotors by type into quality grades. Each grade relates to the product of the specific unbalance eccentricity and the angular service speed. With that relationship, the permissible residual unbalance of a specific rotor can be calculated from its mass and speed: the greater the mass, the more unbalance is tolerated in absolute terms, and the higher the speed, the less is allowed.
How it is applied
- Identify the rotor type to find its recommended quality grade.
- Calculate the permissible residual unbalance from the mass and the service speed.
- Allocate that value among the correction planes according to the geometry.
- After balancing, verify that the measured residual unbalance is within the permitted value.
What it does not cover
- Flexible rotors, which require other criteria.
- The balance tolerance does not by itself guarantee a vibration level in the installed machine, which depends on the base, the bearings and the coupling.
Consulting the current edition
This standard has been revised and its content has been relocated within the ISO family of balancing standards. The current edition must be consulted to confirm which document applies.
An example
A fan rotor that turns faster requires a lower permissible residual unbalance than the same rotor at a lower speed, according to the quality grade relationship. That is why the criterion is always calculated with the actual service speed, and not with the balancing speed if the two differ.