Electronic instrumentation

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • What does IEC 61010-1 establish for measuring equipment?

    IEC 61010-1 sets the general safety requirements for electrical equipment for measurement, control and laboratory use, in order to protect the user against electric shock, burns, fire and other hazards.

  • What does the IEEE 1451 smart transducer series propose?

    The IEEE 1451 series defines a common way to describe sensors and actuators and connect them to a network, so that each transducer identifies itself and delivers data in a standard format without manual configuration.

  • What is a data acquisition system?

    A data acquisition system conditions, samples and digitizes signals from sensors or instruments, then stores them or sends them to a computer for logging, analysis or control.

  • What is a four-wire connection?

    A four-wire connection measures a resistance using one pair of leads to inject the current and a separate pair to measure the voltage, so that the resistance of the leads and contacts does not enter the result.

  • What is a programmable power supply?

    A programmable power supply is a regulated supply whose voltage, current and protections are set through a control port, and which can read back what it delivers so it can be integrated into an automated test.

  • What is a source measure unit?

    A source measure unit, known by the abbreviation SMU, is an instrument that applies a voltage or current and simultaneously measures the complementary quantity on the device under test.

  • What is an electronic load and how does it work?

    An electronic load is an instrument that sinks current from a source under test in a controlled way, using power semiconductors that dissipate the energy as heat and that are programmed in an operating mode.

  • What is common-mode rejection?

    Common-mode rejection is the ability of a differential instrument or amplifier to ignore the signal that appears equally on both inputs and respond only to the difference between them.

  • What is galvanic isolation?

    Galvanic isolation is the electrical separation between two circuits so that signal or energy passes without a direct conductive path, using transformers, optocouplers or capacitive coupling.

  • What is instrumentation amplifier noise?

    Instrumentation amplifier noise is the random signal the circuit itself adds to the measurement; it is specified referred to the input and determines the smallest signal that can be distinguished.

  • What is integration time?

    Integration time is the interval during which an analog-to-digital converter averages the input signal to produce a reading; a longer time reduces noise and mains interference, but makes the measurement slower.

  • What is line and load regulation?

    Line regulation measures how much the output of a power supply changes when the input voltage varies; load regulation, how much it changes when the current demanded varies. Both show how stable the supply keeps its output.

  • What is resolution versus accuracy in an instrument?

    Resolution is the smallest change the instrument can display; accuracy is how close the reading is to the true value. An instrument can have high resolution and poor accuracy.

  • What is the burden of an instrument?

    Burden, or imposed load, is the power or impedance a measuring instrument adds to the circuit when connected to it; if significant, it alters the quantity being measured and produces a loading error.

  • What is the duty cycle of a signal?

    The duty cycle of a signal is the fraction of each period during which the signal is at the high level; it is expressed as a percentage and determines the average value of a pulse signal.

  • What is the input impedance of an instrument?

    The input impedance of an instrument is the load it presents to the circuit being measured; if it is not much higher than the source impedance, the instrument itself alters the signal it is meant to measure.

  • What is the interface defined by IEEE 488?

    IEEE 488 defines a parallel communication bus between instruments and a controller, known as GPIB or HP-IB, which lets you send commands to and read results from several units connected to the same cable.

  • What is thermal drift in an instrument?

    Thermal drift is the slow change in an instrument's reading or output when its temperature varies; it means having to wait for warm-up, control the environment or apply corrections.

  • Why does a multimeter give unstable readings?

    A multimeter gives unstable readings almost always because the signal really is varying, because it is picking up noise or interference on a high-impedance input, or because the contact, range or integration time is not right.

  • Why does a multimeter’s internal fuse blow?

    A multimeter's fuse blows when more current flows through the current range than it can withstand, almost always because current was measured with the probes in the current terminals connected in parallel across a voltage source.

  • Why does a power supply oscillate with certain loads?

    A regulated power supply oscillates when the load and wiring modify its feedback loop and erode its phase margin, which is typical with large capacitive loads, long inductive cables or negative-resistance loads.

  • Why does remote communication with an instrument fail?

    Remote communication with an instrument usually fails because of settings that do not match at both ends, such as address, speed, terminators or protocol, because of cable problems, or because of malformed or badly timed commands.