What sets it apart
A conventional supply is adjusted with knobs. A programmable supply allows its parameters to be set from a program, through interfaces such as USB, LAN or GPIB, normally with SCPI-type text commands. It can also return measurements of output voltage and current, so the same supply acts both as a power source and as a basic measuring instrument.
Operating modes
The supply regulates one of two quantities. In constant voltage mode it maintains the set voltage as long as the load demands less current than the limit. If the load demands more, the supply switches to constant current mode and lets the voltage fall so as not to exceed that limit. The mode it operates in depends on the connected load. This behavior makes it possible to power a circuit safely: a short circuit or a fault does not produce currents higher than those configured.
Common functions
- Protections: overvoltage, overcurrent and temperature limits that shut off the output under an abnormal condition.
- Remote sensing: two additional terminals measure the voltage at the load rather than at the supply output, to compensate for the drop in the cables.
- Ramps and sequences: programmed variation of the output, useful for simulating startups, voltage dips or battery profiles.
- Controlled idle output: enabling or disabling the output from the program and setting its state at power-on.
- Data logging: reading the output to monitor consumption during a test.
How it is used in a test bench
The voltage and current limit appropriate for the unit under test are set, the output is enabled, the stabilization conditions are awaited, and the current drawn is measured. Protection limits are configured before the load is connected. Consumption in different states, such as standby and operation, is a typical measurement.
What to consider when choosing or using one
- Regulation and ripple compatible with the sensitivity of the load.
- Speed of response to sudden load changes.
- Type of load: capacitive, inductive or with current peaks.
- Isolation of the output from ground and the possibility of connecting several supplies in series or in parallel, as permitted by the manufacturer.
When working with hazardous voltages, connections and configuration must be carried out by qualified persons in accordance with the applicable safety regulations.