Antennas

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • What Is a Log-Periodic Antenna?

    A log-periodic antenna is a broadband antenna whose elements are scaled in a geometric progression, so that its properties repeat periodically with the logarithm of frequency and its behavior stays nearly constant over a wide range.

  • What Is a Loop Antenna for Magnetic Field Measurement?

    A loop antenna is a conductive loop that, by induction, delivers a voltage proportional to the component of the magnetic field passing through its area, and it is used to measure magnetic fields over a range of frequencies.

  • What is a radiation pattern?

    A radiation pattern is a representation of how the field or power radiated by an antenna varies with direction, measured in the far field. It shows where the antenna sends energy and where it sends almost none.

  • What is a side lobe?

    A side lobe is a region of the radiation pattern, separate from the main lobe, in which the antenna also radiates or receives energy; it represents radiation in unwanted directions and limits interference rejection.

  • What Is an Anechoic Chamber?

    An anechoic chamber is a shielded enclosure whose walls are covered with material that absorbs electromagnetic waves, so there are no reflections and the antenna under test behaves as if it were in free space.

  • What Is an Antenna Positioner?

    An antenna positioner is an electromechanical device that rotates the antenna under test with angular precision about one or more axes, in order to record its response in each direction and build the radiation pattern.

  • What is an isotropic radiator?

    An isotropic radiator is an ideal, lossless point antenna that radiates the same intensity in all directions; it does not physically exist, but it serves as a reference for expressing directivity and gain.

  • What is antenna gain?

    Antenna gain is the ratio between the power an antenna radiates in a given direction and the power an ideal isotropic antenna fed with the same power would radiate, including the antenna's own losses. It does not create power: it concentrates it in certain directions.

  • What is antenna polarization?

    Antenna polarization describes the orientation and time behavior of the electric field vector of the wave it radiates. It can be linear, circular or elliptical, and the transmitting and receiving antennas must match to avoid losing signal.

  • What is beamwidth?

    Beamwidth is the angular opening of an antenna's main lobe. It is usually taken between the points where the power falls to half the maximum, about three decibels down. The narrower the beam, the higher the gain tends to be.

  • What Is Directivity?

    Directivity is the ratio of an antenna's radiation intensity in a given direction to the average intensity over all directions; it indicates how much the radiated energy is concentrated toward one side compared with a source radiating equally everywhere.

  • What is impedance bandwidth?

    It is the frequency range over which an antenna maintains an acceptable match with its feed line, that is, over which the reflection at its terminals stays below a limit set by the application.

  • What is radiation efficiency?

    Radiation efficiency is the fraction of the power entering the antenna terminals that is actually radiated into space; the rest is dissipated as heat in the conductors and dielectrics of the antenna itself.

  • What is the effective area of an antenna?

    Effective area is the imaginary surface that, multiplied by the power density of the incident wave, gives the power the antenna delivers to a matched load. It is tied to gain and wavelength.

  • What is the far-field region?

    It is the region, at a sufficient distance from the antenna, where the shape of the radiation pattern no longer changes with distance and the wave behaves locally as a plane wave. Gain and pattern measurements are made here.

  • What is the phase center of an antenna?

    The phase center of an antenna is the point from which the radiated wave appears to emanate with spherical phase fronts; it is the correct reference point for measuring distances and aligning the antenna in phase measurements.

  • What Procedures Does the IEEE 149 Standard Describe?

    IEEE 149 describes antenna test procedures: how to set up, measure and report parameters such as radiation pattern, gain, directivity, polarization and impedance, and which field and installation conditions must be met.

  • Why Does a Badly Installed Connector Cause Reflections on an Antenna Line?

    A badly installed connector creates an impedance discontinuity that reflects part of the signal; on a cable and antenna analyzer it appears as a localized reflection peak at the distance of the connector and as degraded return loss.

  • Why Does a Mismatched Antenna Damage a Transmitter?

    A mismatched antenna reflects part of the power back toward the transmitter, and that reflected power adds to the voltage and current in the output stage, which overheats or is subjected to voltages it was not designed to withstand.

  • Why Does an Antenna Exposed to the Weather Degrade?

    An antenna exposed to the weather degrades mainly through corrosion of connectors and contacts, moisture ingress into the line and the radome, and aging of materials from ultraviolet radiation and temperature cycling.

  • Why Does an Antenna’s Resonant Frequency Change When It Is Installed?

    The resonant frequency changes when an antenna is installed because nearby objects, the mast, the mounting surface and the cable alter its near fields and effective capacitance; the antenna measured in open air is not the same as the installed antenna.

  • Why Is Coverage Lost After a Cable Change?

    When coverage is lost after a cable change, the cause is almost always higher attenuation, faulty connectors or adapters, an impedance mismatch or a cable type unsuited to the frequency and length, and not the antenna itself.