What it represents
An antenna does not radiate equally in all directions. The radiation pattern is the function that describes the radiated intensity according to the elevation and azimuth angles, at a distance large enough for the pattern to be independent of it. It can be expressed as electric field, power density or gain, and is normally normalized to the maximum to show the shape.
Elements of a pattern
- Main lobe. The direction of maximum radiation.
- Side lobes. Smaller maxima in other directions. Their level relative to the main lobe indicates how much energy is lost to, or picked up from, unwanted directions.
- Back lobe. Radiation in the direction opposite the main lobe.
- Nulls. Directions where radiation is at a minimum.
How it is presented
A complete three-dimensional pattern is hard to read, so cuts are shown instead. The most commonly used are the E plane, which contains the electric field vector and the direction of maximum radiation, and the H plane, which contains the magnetic field vector and that same direction. Each cut can be plotted in polar coordinates, which give an immediate idea of the shape, or in rectangular coordinates, where side lobe levels and widths can be read more precisely.
Polarization components
A complete pattern includes the co-polar component, which corresponds to the desired polarization, and the cross-polarization component, which is orthogonal to it. The difference between the two in the main direction indicates how pure the polarization is. An antenna with poor cross-polarization can couple unwanted signals or lose power to a properly oriented receiving antenna.
How to interpret a plot
- Locate the maximum and check that it points where expected.
- Read the width of the main lobe at the half-power point.
- Review the level of the side lobes and the nulls.
- Check the symmetry: unexpected asymmetries can come from the antenna, the mounting or reflections in the measurement.
The pattern depends on frequency, so it is measured at the operating frequency and across the band. It also depends on the immediate surroundings: an antenna mounted on a vehicle or a mast has a different pattern from the one measured in isolation.